JENNAR JDAF3924RX Undercounter Dishwasher
Undercounter Dishwasher
■ Included water inlet hose with Leak Detection System for some
models.
PRODUCT MODEL NUMBERS
JDAF3924RX
JDAF5924RX
JDAF5924RL
JDAF5924RM
■ Included 3/8" (9.5 mm) Compression x 3/4" (19 mm) Water inlet
adapter (only for models with Leak Detection System).
■ If installed in new construction, make sure the house water
supply lines have been flushed prior to connecting the
dishwasher to remove any debris that may exist in the supply
line.
DRAIN REQUIREMENTS
■ A new drain hose is supplied with your dishwasher. If drain
hose is not long enough, use a drain hose extension with a
maximum length of 12 ft (3.7 m).
ELECTRICAL REQUIREMENTS
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code,
ANSI/NFPA 70 - latest edition, and all local codes and
ordinances.
■ Make sure to connect drain hose to waste tee or disposer
inlet above drain trap in house plumbing and 20" (508 mm)
minimum above the floor. It is recommended that the drain
hose either be looped up and securely fastened to the
underside of the counter or be connected to an air gap.
For a fee, a copy of the above code standards can be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
You Must Have:
IMPORTANT: This product is not equipped with a high loop on
the side of the dishwasher. The installer is responsible for adding
a high loop in the adjacent cabinet. A high loop is required if
the dishwasher will drain into a floor drain. This prevents water
draw off from the dishwasher during operation. When the drain
is connected to a sink drain, counter-top air-gap or disposer, the
high loop is generally not required. An check valve internal to the
drain prevents back-flow into the dishwasher.
■ 120 V, 60 Hz, AC only, 15 A or 20 A, fused electrical supply.
■ Copper wire only.
■ Make sure to use an air gap if the drain hose is connected to
house plumbing lower than 20" (508 mm) above subfloor or
floor.
■ A maximum of 2 field wiring supply conductors (12 AWG
largest size) plus 1 grounding conductor are permitted in the
terminal box.
We Recommend:
Use of air gap
■ Install the dishwasher on a circuit with appropriate interrupte
per your local code. The dishwasher is compatible with tim
delay fuses, standard circuit breakers, and GFCI and AFCI
circuit breakers.
Circuit Requirement:
Air gap
■ The dishwasher may be installed on the same circuit as a
garbage disposal providing that the branch circuit cannot
exceed rated circuit load and must comply with all governing
codes and regulations such as but not limited to National
Electrical Code, ANSI/NFPA 70 - latest edition.
■ No electrical connections other than the dishwasher power
and ground connections can be made inside of the dishwasher
junction box.
If Connecting Dishwasher with a Power Cord:
■ If required, the air gap should be installed in accordance with
the air gap installation instructions. When you are connecting
the air gap, a rubber hose (not provided) will be needed to
connect to the waste tee or disposer inlet.
■ Use UL Listed power cord kit marked for use with
dishwasher. See the “Tools and Parts” section at
the front of the Owner’s manual for part details and
orders.
■ Use 1/2" (13 mm) minimum I.D. drain line fittings.
■ Plug into a grounded 3 prong outlet. Outlet must meet
all local codes and ordinances.
WATER SUPPLY REQUIREMENTS
If Connecting Dishwasher with Direct Wiring:
■ This dishwasher maybe fitted with a smart inlet hose with a
water cut off valve. Do not cut the water inlet hose for any
reason, to install, adapt or shorten.
■ Use flexible, armored, or nonmetallic sheathed copper
wire with grounding wire that meets the
wiring requirements for your home and
local codes and ordinances.
■ This dishwasher has a water heating feature and also requires
a connection to a hot water supply line.
■ Use only the supplied plastic cable fittings for flexible and
non-metallic sheathed wiring (Romex, etc.). Do not use metallic
strain reliefs for these wire constructions.
■ A hot water line with 20 psi to 120 psi (138 kPa to 862 kPa)
water pressure can be verified by a licensed plumber.
■ Use a UL-listed/CSA-approved metallic strain relief for armored
cable installations (21 mm diameter), Using the strain relief’s
manufacturer installations instructions.
■ 120°F (49°C) water at dishwasher.
■ 3/8" (95 mm) O.D. copper tubing with compression fitting or
flexible braided water supply line.
Dimensions are for planning purposes only. For complete details, see
Installation Instructions packed with product. Specifications subject to
change without notice.
Because Whirlpool Corporation policy includes a continuous commitment
to improve our products, we reserve the right to change materials and
specifications without notice.
W11589944B
1
| General | Details |
|---|---|
| Name | JENNAR JDAF3924RX Undercounter Dishwasher |
| Make | JENNAR |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.23 MB |

JENNAR JDAF3924RX Undercounter Dishwasher Overview
Summary of Contents
- Page 1: Undercounter dishwasher includes a water inlet hose with a leak detection system for some models. Product model numbers include JDAF3924RX, JDAF5924RX, JDAF5924RL, and JDAF5924RM. A new drain hose is supplied with the dishwasher, and if it's not long enough, a drain hose extension can be used. Electrical connection and wire size must conform to the National Electrical Code and local codes. The installer must add a high loop in the adjacent cabinet if the dishwasher drains into a floor drain. A maximum of 2 field wiring supply conductors plus 1 grounding conductor are permitted in the terminal box. If connecting the dishwasher with a power cord, a UL Listed power cord kit must be used. The dishwasher may be fitted with a smart inlet hose with a water cut-off valve. A hot water line with 20 psi to 120 psi water pressure is required. Dimensions are for planning purposes only, and specifications are subject to change without notice.
- Page 2: Product dimensions A. 32 1/4-35 7/16 (820-900 mm) E. 14 1/16 (358 mm) C. 23 9/16 (599 mm) B. 22 5/8 (574 mm) D. 28 3/8 (721 mm) F. 18 3/4 (477 mm) Product dimensions (for panel ready models) A. 32 1/4-35 7/16 (820-900 mm) C. 23 9/16 (599 mm) B. 21 7/8 (555 mm) D. 18 3/4 (477 mm) G. 28 3/8-29 15/16 (720-760 mm) Note: If a custom toe kick is desired to be installed, adjust the thickness of the custom panel to make it flush with the cabinet toe kick. Dimensions are for planning purposes only. Specifications subject to change without notice.
- Page 3: Cabinet opening dimensions A. 32 1/4-35 7/16 (820-900 mm) measured from the lowest point on the underside of the countertop. B. 24 (609.6 mm) Minimum C. 23 5/8-24 1/4 (600-616 mm) Minimum, measured from narrowest point of opening. Dimensions are for planning purposes only. Specifications subject to change without notice. Whirlpool Corporation policy includes a continuous commitment to improve our products.
- Page 4: Lave-vaisselle sous comptoir Adaptateur de compression de 3/8 po (9,5 mm) x 3/4 po (19 mm) inclus pour l’arrivée d’eau. S’il est installé dans une nouvelle construction, vous assurer que l’entrée d’eau de la maison a été nettoyée avant d’effectuer le branchement. Un tuyau d’évacuation neuf est fourni avec le lave-vaisselle. S’assurer que le raccordement électrique est adéquat et conforme au Code National de l’Électricité. Veiller à raccorder le tuyau d’évacuation à la canalisation d’égout en T ou au raccord de broyeur à déchets. Ce produit n’est pas équipé d’une boucle surélevée sur le côté du lave-vaisselle. Alimentation de 120 V CA à 60 Hz et protégée par un fusible de 15 ou 20 A. Utiliser un cordon d’alimentation homologué UL conçu pour utilisation avec un lave-vaisselle. Ce lave-vaisselle peut être équipé d’un tuyau d’arrivée intelligent avec une vanne de coupure d’eau. Température de 120 °F (49 °C) à l’entrée du lave-vaisselle.
- Page 5: Dimensions du produit C. 23 9/16 po (599 mm) A. 32 1/4 po-35 7/16 po (820-900 mm) E. 14 1/16 po (358 mm) B. 22 5/8 po (574 mm) D. 28 3/8 po (721 mm) F. 18 3/4 po (477 mm) Dimensions du produit (pour les modèles avec panneau prêt-à-installer) A. 32 1/4 po-35 7/16 po (820-900 mm) C. 23 9/16 po (599 mm) B. 21 7/8 po (555 mm) Remarque : Pour installer une plinthe personnalisée, ajuster l’épaisseur du panneau personnalisé pour qu’il soit au même niveau que la plinthe du meuble.
- Page 6: Dimensions de l’ouverture de l’armoire A. 32 1/4 po à 35 7/16 po (820 à 900 mm) depuis le point le plus bas de la face inférieure du plan de travail. B. Minimum de 24 po (609,6 mm) C. 23 5/8 po-24 1/4 po (600-616 mm) minimum mesuré au point le plus étroit de l’ouverture. Les dimensions sont indiquées à des fins de planification uniquement. Pour des détails complets, voir les instructions d’installation fournies avec le produit. Spécifications indiquées sous réserve de modifications. La politique de Whirlpool Corporation, c’est aussi notre engagement à travailler sans relâche à l’amélioration de nos produits.
- Page 7: Lavavajillas para instalarse debajo del mostrador Tubería de cobre con un diámetro externo de 3/8 (9,5 mm) con racor con conexión de compresión o tubería de suministro de agua trenzada flexible. Manguera de entrada de agua incluida con Sistema de Detección de Fugas para algunos modelos. Requisitos de desagüe Asegúrese de conectar la manguera de desagüe al conector de residuos en “T” o a la entrada del colector de residuos sobre el sifón de desagüe en la plomería de la casa. Requisitos eléctricos Este producto no está equipado con un circuito alto en el lateral del lavavajillas. Asegúrese de utilizar una purga de aire si la manguera de desagüe está conectada a la plomería de la casa a una altura menor de 20 (508 mm) sobre el contrapiso o el piso. Requisitos de suministro de agua Este lavavajillas puede estar equipado con una manguera de entrada inteligente con válvula de corte de agua. Agua a 120 °F (49 °C) en el lavavajillas.
- Page 8: Dimensiones del producto C. 23 9/16 (599 mm) A. 32 1/4-35 7/16 (820-900 mm) B. 22 5/8 (574 mm) D. 28 3/8 (721 mm) E. 14 1/16 (358 mm) F. 18 3/4 (477 mm) Dimensiones del producto (para modelos listos para panel) A. 32 1/4-35 7/16 (820-900 mm) B. 21 7/8 (555 mm) D. 18 3/4 (477 mm) Nota: Si se desea instalar un zócalo a medida, ajuste el grosor del panel a medida para que quede enrasado con el zócalo del gabinete. Las dimensiones son solo para fines de planificación.
- Page 9: Dimensiones de la abertura del gabinete A. 32 1/4-35 7/16 (820-900 mm) medido desde el punto más bajo de la parte inferior del mostrado. B. 24 (609,6 mm) Mínimo. C. 23 5/8-24 1/4 (600-616 mm) Mínimo, medido desde el punto más estrecho de la abertura. Las dimensiones son solo para fines de planificación. Para obtener los detalles completos, vea las Instrucciones de Instalación incluidas con el producto. Las especificaciones están sujetas a cambio sin previo aviso.