CMA UC65e M3 Undercounter Dishwasher
Parameter Setting Instructions
PARAMETER SETTINGS INSTRUCTIONS
0514058 REV A -30-MAR-2021
CAUTION: Parameter changes must be made
by qualified personnel only.
!
Locate control board shown below:
(LCD SCREEN)
Open door.
WASH TEMPERATURE
ADJUSTMENT
in cycle
wait
152
PRESS BUTTON TO CYCLE
THROUGH AVAILABLE
VALUES
The following parameters may be changed
depending on model:
Unscrew two
fasteners after
opening door.
Displace control
panel safely and
securely.
!
1. DETERGENT CONCENTRATION
2. RINSE TEMP
3. WASH TEMP
DO NOT PULL.
BOARD SETTINGS
ARE ACCESSED
FROM REAR OF
CONTROL PANEL.
4. FILL TIME
5. UNITS (F-C)
6. LANGUAGE (English - French)
SKIP advances
to the next portion
of a cycle.
Menu Button
push and hold for
menu, then scroll
parameter.
Change
Parameters.
Viewed from the back of the machine
(Back of the board shown below)
(PARAMETER BUTTONS ON BOARD)
PARAMETER SETTINGS (continued)
Skip
Select
Menu
To Change Parameters:
1. Push and Hold the “Menu”button.
3. Push menu button to scroll through until desired parameter is reached.
4. Push “CHANGE” button until desired setting is reached.
5. Release and control will return to normal operation (approximately 3 seconds).