208V or 240V electrical connections (CUH and EUH Only)  
The 208V or 240V electrical connection for the CUH machine requires two hot wires and  
a ground. There is no current carrying neutral used.  
CUH & EUH (208-240V/60Hz/1Ph)  
CUL & EUL (120V/60Hz/1Ph)  
5.6.3 Transformer connections (CUH Only)  
NOTICE!  
Transformer connections (CUH and EUH Only)  
For the CUH and EUH machines a control transformer is used to step the 208V or 240V  
incoming power to 120V for the control circuitry and drain pump. The transformer is  
factory-preset to 240V.  
For 208V incoming power, relocate the 1T-H wire on the transformer from the 240V terminal to the  
208V terminal (See below for correct setup) Refer to wiring diagram supplied with machine.  
Note: Access transformer by tipping machine up and removing bottom panel.  
An incorrectly connected transformer can lead to machine draining issues.  