6.3 Preparing sanitizer chemical level sensor (CUL only)
6.3.1 Attaching the sanitizer chemical level sensor to the sanitizer tubing
Locate the sanitizer chemical level sensor that was
packaged with the CUL machine.
Note: The sanitizer chemical level sensor will
have a blue stopper and blue sensor wire.
Push the clear sanitizer
tubing all the way onto the
stem end of the sanitizer
chemical level sensor.
6.3.2 Connecting the sanitizer chemical level sensor control wire to the machine
Locate the chemical level sensor electrical
connectors plugs on the back of the machine.
D = Detergent sensor electrical connection
R = Rinse Aid sensor electrical connection
S = Sanitizer sensor electrical connection
Remove the electrical jumper plug from the Sanitizer sensor
connection
Attach the electrical plug from the sanitizer chemical level sensor
6.4 Installing optional detergent and rinse aid chemical level sensors
6.4.1 Connecting the chemical level sensors to the detergent and rinse aid tubing
Refer to instructions supplied with the chemical level sensor accessory kit.
6.4.2 Connecting the detergent and rinse aid chemical level sensor control wires to the machine
Refer to instructions supplied with the chemical level sensor accessory kit.
Page 21 of 50
Ver3.0
F41138 (August 2022)
| General | Details |
|---|---|
| Name | Centerline CUH-130363 Commercial Dishwasher |
| Make | Centerline |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.75 MB |

Centerline CDH ML-130374 Commercial Dishwasher

centerline CDH-1 51 Racks Hour Door Type Dishwasher