Home > Centerline > centerline CDH-1 51 Racks Hour Door Type Dishwasher

centerline CDH-1 51 Racks Hour Door Type Dishwasher

CUH/CUL  
CDH/CDL  
SCAN TO VISIT THE  
CENTERLINERESOURCE CENTER  
OPERATION and ERROR CARD  
2
3
5
4
1
7
6
4. DELIME BUTTON*  
1. POWER/DRAIN BUTTON  
Pressing and holding (3 seconds) activates  
the deliming cycle.  
Pressing this button switches the machine  
on, fills and heats the wash tank. Pressing  
and holding (3 seconds) activates self-  
cleaning cycle, drains machine, and then  
switches the machine off automatically.  
After machine is switched off, however, the  
machine still has voltage.  
5. TEMPERATURE DISPLAY, WASH TANK  
Displays wash tank temperature while  
machine is in ready state or in a wash cycle.  
6. TEMPERATURE DISPLAY, RINSE  
Displays rinse temperature only when rinse is  
active.  
2. START BUTTON  
CUH & CUL  
CDH & CDL  
Pressing this button  
starts the wash  
cycle. If pressed  
a 2nd time within  
10 seconds of the  
first press, the  
After closing the  
door to start the  
wash cycle, pressing  
this button within  
10 seconds of  
7. TEMPERATURE UNITS  
LED lights for °F or °C.  
WASH PROGRAM  
CUH & CUL  
CDH & CDL  
Normal wash  
the cycle starting  
activates the  
Normal wash  
for average soiled  
dishes – 2 minutes  
extended wash cycle  
is activated.  
for average soiled  
dishes – 1 minute  
extended wash cycle.  
Extended wash  
for heavy soiled  
dishes – 3 to 6  
minutes*  
Extended wash  
for heavy soiled  
dishes – 3 to 6  
minutes*  
3. MENU BUTTON*  
Pressing this button enters the configuration  
menu.  
*For more detail review Operation and Install manual  
ERROR  
SYMPTOM  
CODE  
POSSIBLE SOLUTION*  
1. Press the power button to power off (Provide 20 min to cool off).  
Booster Temperature  
2. Restart as normal.  
01  
Temperature above upper limit  
3. If error continues to display, possible high limit trip or heating element malfunction – contact  
Hobart Service.  
1. Press the power button to power off.  
Booster Temperature  
2. Restart as normal.  
02  
Temperature below lower limit  
3. If error continues to display, possible high limit trip or heating element malfunction – contact  
Hobart Service.  
GeneralDetails
Namecenterline CDH-1 51 Racks Hour Door Type Dishwasher
MakeCenterline
LanguageEnglish
FiletypePDF (Download)
File size0.07 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Centerline CDH ML-130374 Commercial Dishwasher
Centerline CDH ML-130374 Commercial Dishwasher
Centerline CUH-130363 Commercial Dishwasher
Centerline CUH-130363 Commercial Dishwasher

centerline CDH-1 51 Racks Hour Door Type Dishwasher
Free PDF manual for the centerline CDH-1 51 Racks Hour Door Type Dishwasher – with cycle guides, troubleshooting tips, and maintenance instructions 👉 View PDF online or download now and keep your dishwasher running flawlessly!

centerline CDH-1 51 Racks Hour Door Type Dishwasher Overview

Summary of Contents

  • Page 1: Operation and error card Delime button activates the deliming cycle. Power/drain button switches the machine on, fills and heats the wash tank, and activates self-cleaning cycle. Temperature display shows wash tank temperature in ready state or wash cycle. Temperature display for rinse shows rinse temperature only when active. Start button initiates the wash cycle. Menu button enters the configuration menu. Normal wash cycle is for average soiled dishes. Extended wash cycles are available for heavy soiled dishes. Error codes provide possible solutions for temperature issues. Contact Hobart Service for persistent error displays.
  • Page 2: Error codes and symptoms are listed for troubleshooting. When the booster does not reach temperature or water level, a long wash cycle will trigger. If the error continues, it may indicate a high limit trip or heating element malfunction. Press the power button to power off and allow the machine to cool off. For voltage issues, check the booster and wash tank pressure level sensors. Verify that the drain hose is not pinched or kinked to avoid drain overflow limits. Check for clogged nozzles in wash and rinse arms if the fill time is exceeded. Low or no chemicals can cause a chemical deficiency error. Ensure the door is closed during fill, wash, or delime cycles to avoid program interruptions. Rinse temperature must meet or exceed the setpoint to clear low rinse temperature errors. If USB drive issues arise, it may be due to improper configuration or incorrect directory path.