Home > Whirlpool > Whirlpool DU810SWP Undercounter Dishwasher

Whirlpool DU810SWP Undercounter Dishwasher

Undercounter Dishwasher  
PRODUCT MODEL NUMBERS  
DU810SWP DU850SWP  
OVERALL DIMENSIONS  
2378" (60.6 cm)  
24" (61 cm)*  
DU811SWP  
Electrical: 120-volt, 60 Hz, AC-only, 15 or  
20 amp, fused electrical supply. Use copper wire  
only. A time-delay fuse or circuit breaker and  
separate circuit is recommended.  
3378  
(86 cm) min.  
"
Water: A hot water line with 20-120 psi (138-  
862 kPa) water pressure. Water temperature must  
be 120°F (49°C) at dishwasher. Use ³⁄₈" O.D. copper  
tubing with compression fitting or flexible braided  
fill line (1/2" minimum plastic tubing is optional but  
not recommended). Use a ³⁄₈" compression x ³⁄₄"  
hose fitting to connect to water inlet valve. Do not  
solder within 6" (15.2 cm) from water inlet valve.  
*to front of  
door frame  
2034  
"
(52.7 cm)  
Drain: A new drain hose is supplied with  
your dishwasher. If this is not long enough, use a  
new drain hose with a maximum length of 12'  
(3.7 m) (Part Number 3385556) that meets all  
current AHAM/IAPMO test standards, is resistant to  
heat and detergent, and fits the 1" (2.5 cm) drain  
connector of the dishwasher.  
SIDE VIEW  
REAR VIEW  
CABINET OPENING DIMENSIONS  
Make sure to connect the drain hose to waste tee or  
disposer inlet above drain trap in house plumbing  
and 20" (50.8 cm) minimum above the floor. It is  
recommended that  
air gap  
24" (61 cm)**  
the drain hose either  
be looped up and  
securely fastened to  
the underside of the  
counter, or be  
*Measured from the lowest point on the  
underside of countertop.  
**Minimum, measured from narrowest point  
of opening.  
connected to an air  
gap.  
24" (61 cm)  
34" (86.4 cm) min.*  
Make sure to use an  
air gap if the drain hose is connected to house  
plumbing lower than 20" (50.8 cm) above subfloor  
or floor. Use ¹⁄₂" (1.3 cm) minimum I.D. drain line  
fittings.  
6"(15.2 cm)  
4" (10.2 cm)  
6"(15.2 cm)  
If required, the air gap should be installed in  
accordance with the air gap installation instructions.  
When you are connecting the air gap a rubber hose  
(not provided) will be needed to connect to the  
waste tee or disposer inlet.  
4"  
(10.2 cm)  
4"  
(10.2 cm)  
10"  
(25.4 cm)  
21  
(6.4 cm)  
2"  
21  
(6.4 cm)  
2"  
Corner location: Requires a 2" (5.1 cm)  
minimum clearance between the side of the  
dishwasher door and wall or cabinet.  
2"  
(5.1 cm)  
5" (12.7 cm)  
5" (12.7 cm)  
2"  
(5.1 cm)  
A side panel kit is available from your dealer for  
installing your dishwasher at end of cabinet.  
Water line entering through the  
left side of opening in shaded  
areas makes connection easier.  
Minimum 12" (12,7 mm) hole.  
Drain hose and power supply line entering through the right  
side of opening in shaded areas makes connection easier.  
Drain hose size: 112" (3.8 cm)  
Power supply line hole-direct wired: 34" (1.9 cm)  
Power supply line hole-with plug: 112" (3.8 cm)  
Grommet is required for electrical cable or power  
supply cord hole cut in a metal cabinet.  
Do not install dishwasher over carpeted floor.  
Page 1 of 2  
Dimensions are for planning purposes only. For complete details, see Installation Ref. W10282559-D-WH  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
6/19/12  
Instructions packed with product. Specifications subject to change without notice.  
GeneralDetails
NameWhirlpool DU810SWP Undercounter Dishwasher
MakeWhirlpool
LanguageEnglish
FiletypePDF (Download)
File size0.1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Whirlpool 2B19 Dishwasher
Whirlpool 2B19 Dishwasher
Whirlpool WFO3O33PLAUS Standard Dishwasher
Whirlpool WFO3O33PLAUS Standard Dishwasher
Whirlpool W11323304G Dishwasher
Whirlpool W11323304G Dishwasher
Whirlpool WH7IPC15BM60 Dishwasher
Whirlpool WH7IPC15BM60 Dishwasher
Whirlpool FINPUTSAD Dishwasher
Whirlpool FINPUTSAD Dishwasher
Whirlpool W7U HS31 X Dishwasher
Whirlpool W7U HS31 X Dishwasher
Whirlpool Thron Dishwasher
Whirlpool Thron Dishwasher
Whirlpool WDF332PAMS 24 Front Tall Tub Dishwasher
Whirlpool WDF332PAMS 24 Front Tall Tub Dishwasher
Whirlpool WRF540CWHZ Dishwasher
Whirlpool WRF540CWHZ Dishwasher
Whirlpool WDF130PAHB Dishwasher
Whirlpool WDF130PAHB Dishwasher

Whirlpool DU810SWP Undercounter Dishwasher
Free PDF manual for the Whirlpool DU810SWP Undercounter Dishwasher – with cycle guides, troubleshooting tips, and maintenance instructions 👉 View PDF online or download now and keep your dishwasher running flawlessly!

Whirlpool DU810SWP Undercounter Dishwasher Overview

Summary of Contents

  • Page 1: Undercounter dishwasher model numbers include DU810SWP, DU850SWP, and DU811SWP. Overall dimensions are 23 7/8 (60.6 cm) in height and 24 (61 cm) in width. Electrical requirements include a 120-volt, 60 Hz, AC-only supply with a 15 or 20 amp fused electrical supply. A hot water line must have a pressure of 20-120 psi (138-862 kPa) and a temperature of 120°F (49°C) at the dishwasher. A new drain hose is supplied, and if longer is needed, it should meet current AHAM/IAPMO test standards. The drain hose must be connected above the drain trap in house plumbing and at least 20 (50.8 cm) above the floor. An air gap is recommended if the drain hose connects to plumbing lower than 20 (50.8 cm) above the subfloor. A side panel kit is available for installing the dishwasher at the end of a cabinet. Clearance of 2 (5.1 cm) is required between the dishwasher door and wall or cabinet for corner locations. Dimensions provided are for planning purposes only, and specifications are subject to change without notice.
  • Page 2: Custom front panel dimensions are specific to models with frames around the door and access panels. The door panel has a thickness of 7/32 (5.6 mm). The access panel is wider than the door panel. All edges should be routed to 7/32 (5.6 mm) thickness. Cut the door panel to clear the access panel when the door is in the open position. Custom door panels thicker than 7/32 (5.6 mm) require routing at the top and bottom. Custom access panels thicker than 7/32 (5.6 mm) should have all four sides routed to 7/32 (5.6 mm) thickness. For panels less than 7/32 (5.6 mm) thick, install spacers behind the panels. Dimensions provided are for planning purposes only. Specifications are subject to change without notice.