Whirlpool WDF332PAMW Full Console Dishwasher
Undercounter Dishwasher
■ 3/8" (95 mm) O.D. copper tubing with compression fitting or
flexible braided water supply line. See the “Tools and Parts”
section at the front of the guide for part details and orders.
PRODUCT MODEL NUMBERS
WDF110PAB
WDF111PAB
WDF120PAF
WDF121PAF
WDF130PAH
WDF131PAH
WDF320PAD
WDF330PAH
WDF331PAH
WDF331PAM
WDF340PAM
WDF520PAD
WDF540PAD
WDF545PAF
WDT530HAM
WDT540HAM
WDT710PAH
WDT720PAD
WDT730HAM
WDT730PAH
WDT735PAG
WDT735PAH
WDP540HAM
WDP560HAM
WDP730HAM
WDF332PAM**
WDF341PAP**
WDT531HAP**
NOTE: 1/2" (13 mm) minimum plastic tubing is not
recommended.
■ A 90° elbow with 3/4" (95 mm) hose connection with rubber
washer. See the “Tools and Parts” section at the front of the
guide for part details and orders.
■ Do not solder within 6" (152 mm) of the water inlet valve.
■ If installed in new construction, make sure the house water
supply lines have been flushed prior to connecting the
dishwasher to remove any debris that may exist in the supply
line.
DRAIN REQUIREMENTS
■ A new drain hose is supplied with your dishwasher. If drain
hose is not long enough, use a new drain hose with a
maximum length of 12 ft (3.7 m) that meets all current
AHAM/ IAPMO test standards, is resistant to heat and
detergent, and fits the 1" (25 mm) drain connector of the
dishwasher. See the “Tools and Parts” section at the front of
the guide for part details and orders.
NOTE: If replacing an existing dishwasher, it is
recommended to install a new water line (see the “Tools and
Parts” section at the front of the guide for part details) and
drain hose (supplied) with the new dishwasher.
ELECTRICAL REQUIREMENTS
■ Make sure to connect drain hose to waste tee or disposer
inlet above drain trap in house plumbing and 20" (508 mm)
minimum above the floor. It is recommended that the drain
hose either be looped up and securely fastened to the
underside of the counter or be connected to an air gap.
WARNING
■ Make sure to use an air gap if the drain hose is connected to
house plumbing lower than 20" (508 mm) above subfloor or
floor.
Use of air gap
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Air gap
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
You Must Have:
■ 120 V, 60 Hz, AC only, 15 A or 20 A, fused electrical supply.
■ Copper wire only.
■ If required, the air gap should be installed in accordance with
the air gap installation instructions. When you are connecting
the air gap, a rubber hose (not provided) will be needed to
connect to the waste tee or disposer inlet.
■ A maximum of 2 field wiring supply conductors (12 AWG
largest size) plus 1 grounding conductor are permitted in the
terminal box.
■ Use 1/2" (13 mm) minimum I.D. drain line fittings.
We Recommend:
■ A time-delay fuse or circuit breaker.
■ A separate circuit.
WATER SUPPLY REQUIREMENTS
■ This dishwasher has a water heating feature and also requires
a connection to a hot water supply line.
If Connecting Dishwasher with a Power Cord:
■ A hot water line with 20 psi to 120 psi (138 kPa to 862 kPa)
water pressure can be verified by a licensed plumber.
■ Use UL Listed power cord kit marked for use with
dishwasher. See the “Tools and Parts” section at the
front of the guide for part details and orders.
■ 120°F (49°C) water at dishwasher.
■ Plug into a grounded 3 prong outlet. Outlet must meet
all local codes and ordinances.
Dimensions are for planning purposes only. For complete details, see
Installation Instructions packed with product. Specifications subject to
change without notice.
Because Whirlpool Corporation policy includes a continuous commitment
to improve our products, we reserve the right to change materials and
specifications without notice.
W11542837B
1
| General | Details |
|---|---|
| Name | Whirlpool WDF332PAMW Full Console Dishwasher |
| Make | Whirlpool |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.51 MB |

Whirlpool 2B19 Dishwasher

Whirlpool WFO3O33PLAUS Standard Dishwasher

Whirlpool W11323304G Dishwasher

Whirlpool WH7IPC15BM60 Dishwasher

Whirlpool FINPUTSAD Dishwasher

Whirlpool W7U HS31 X Dishwasher

Whirlpool Thron Dishwasher

Whirlpool WDF332PAMS 24 Front Tall Tub Dishwasher

Whirlpool WRF540CWHZ Dishwasher

Whirlpool WDF130PAHB Dishwasher

Whirlpool WDF332PAMW Full Console Dishwasher Overview
Summary of Contents
- Page 1: Undercounter dishwasher requires specific installation components, including 3/8 copper tubing or flexible braided water supply line. Product model numbers include WDF110PAB, WDF111PAB, WDF120PAF, among others. A new drain hose is supplied, and if longer is needed, it must meet current AHAM/IAPMO standards. The drain hose should be connected above the drain trap in house plumbing, at least 20 above the floor. An air gap is necessary if the drain hose is connected lower than 20 above the subfloor. Electrical requirements include a grounded 3 prong outlet and a 120V, 60Hz, AC only, 15A or 20A fused electrical supply. The dishwasher requires a connection to a hot water supply line with specific pressure requirements. Use of a time-delay fuse or circuit breaker and a separate circuit is recommended. The installation instructions should be followed for proper setup, and specifications are subject to change. Dimensions provided are for planning purposes only, and complete details are available in the installation instructions.
- Page 2: If connecting dishwasher with direct wiring, use a UL Listed/CSA Approved metallic strain relief. Use flexible, armored, or nonmetallic sheathed copper wire with grounding wire that meets the wiring requirements for your home and local codes and ordinances. Product dimensions for 331 and 340 models include various measurements such as 25¼ (641 mm) and 30 (762 mm). For 4 (100 mm) toe kick, height of cabinet opening is 34½ (863 mm). Insulation may be compressed (not used on all models). Product dimensions for 500 and 700 models also include measurements like 25¼ (641 mm) and 30 (762 mm). Door handles may protrude forward of the face of the dishwasher, varying by model. Dimensions are for planning purposes only; for complete details, see installation instructions packed with the product. Specifications are subject to change without notice. Whirlpool Corporation reserves the right to change materials and specifications without notice.
- Page 3: Cabinet opening dimensions are specified. Shaded areas of cabinet walls indicate where utility connections may be installed. Measurements include 10 1/2 (267 mm) and 34 (864 mm). The lowest point on the underside of the countertop is used for measurement. Height may be reduced to 33 1/2 (851 mm) by removing wheels and insulation. Minimum height is measured from the narrowest point of the opening. Additional measurements include 4, 6 3/4 (172 mm), 3, 6 1/4 (159 mm), 2 1/4 (64 mm), 1 3/4 (44 mm), and 2 (51 mm). Two 24 (620 mm) measurements are noted. Dimensions are crucial for proper installation. Ensure all measurements are accurate for optimal utility connection.
- Page 4: Lave-vaisselle sous comptoir Température de 120 °F (49 °C) à l’entrée du lave-vaisselle. Numéros de modèle du produit. Tube de cuivre de 3/8 po (95 mm) de diamètre externe avec raccord de compression ou canalisation d’alimentation en eau flexible. Exigences d’évacuation. Un tuyau d’évacuation neuf est fourni avec le lave-vaisselle. S’assurer que l’entrée d’eau de la maison a été nettoyée avant le branchement. Veiller à raccorder le tuyau d’évacuation à la canalisation d’égout en T. Spécifications électriques. Utiliser un dispositif de brise-siphon si le tuyau d’évacuation est raccordé à moins de 20 po (508 mm) au-dessus du sous-plancher. Alimentation de 120 V CA à 60 Hz et protégée par un fusible de 15 ou 20 A.
- Page 5: Pour le raccordement direct du lave-vaisselle, il est important d'utiliser des conducteurs de cuivre gainés non métalliques ou blindés souples avec conducteur de liaison à la terre. Ces conducteurs doivent satisfaire aux exigences de l’installation électrique du domicile et être conformes aux prescriptions des codes et règlements locaux. Il est recommandé d'utiliser un cordon d’alimentation homologué UL conçu pour utilisation avec un lave-vaisselle. Un serre-câbles homologué UL ou CSA doit être utilisé. L’appareil doit être branché sur une prise à 3 alvéoles reliée à la terre, conforme à tous les codes et règlements locaux. Les dimensions du produit pour les modèles 331 et 340 incluent des mesures spécifiques pour la planification. Les dimensions sont fournies à des fins de planification uniquement et pour des détails complets, il est conseillé de consulter les Instructions d’installation fournies avec le produit. Les spécifications indiquées sont sous réserve de modifications. Whirlpool Corporation s'engage à travailler à l’amélioration de ses produits et se réserve le droit de modifier les matériaux et spécifications sans préavis.
- Page 6: Dimensions du produit pour les modèles 500 et 700. La hauteur de l’ouverture est de 34 1/2 po (863 mm) pour un coup-de-pied de 4 po (100 mm). L’isolant peut être comprimé sur certains modèles. Les poignées de porte peuvent dépasser vers la façade du lave-vaisselle, cela varie selon le modèle. Dimensions de l’ouverture de l’armoire. Les zones grisées des parois de l’armoire indiquent les endroits où les raccordements électriques peuvent être installés. Mesurer depuis le point le plus bas de la face inférieure du comptoir. Cette dimension peut être réduite à 33 1/2 po (851 mm) en retirant les roulettes du lave-vaisselle. Dimension minimale mesurée au point le plus étroit de l’ouverture.
- Page 7: Lavavajillas para instalarse debajo del mostrador Una tubería de agua caliente con presión de agua de 20 psi a 120 psi (de 138 kPa a 862 kPa), que pueda ser verificada por un plomero autorizado. Agua a 120 °F (49 °C) en la lavavajillas. Se provee una manguera nueva de desagüe con su lavavajillas. No suelde a una distancia menor de 6 (152 mm) de la válvula de entrada del agua. Asegúrese de conectar la manguera de desagüe al colector de residuos en “T” o a la entrada del colector de residuos sobre el sifón de desagüe en la plomería de la casa. Asegúrese de utilizar una purga de aire si la manguera de desagüe está conectada a la plomería de la casa a una altura menor de 20 (508 mm) sobre el contrapiso o el piso. Conecte a un contacto de pared de conexión a tierra de 3 terminales. No quite la terminal de conexión a tierra. Esta lavavajilla tiene una función de calentamiento de agua y también requiere una conexión a una tubería de suministro de agua caliente.
- Page 8: Conexión del lavavajillas con cableado directo: Un fusible retardador o un disyuntor. Un circuito separado. Utilice un cable de cobre flexible, blindado o con una funda no metálica con un cable de conexión a tierra que cumpla con los requisitos de cableado para su hogar y con los códigos y ordenanzas locales. Conexión del lavavajillas con un cable de alimentación: Utilice un protector de cables con certificación UL/homologación CSA. Use un cable de suministro de energía con certificación UL para uso con lavavajillas. Conecte a un tomacorriente con conexión a tierra de 3 terminales. Dimensiones del producto (para modelos 331 y 340): Las dimensiones son solo para fines de planificación. Para obtener los detalles completos, vea las instrucciones de instalación incluidas con el producto. Las especificaciones están sujetas a cambio sin previo aviso.
- Page 9: Dimensiones del producto (para modelos 500 y 700) Para un zoclo de 100 mm (4), la altura de la abertura del gabinete es de 863 mm (34 1/2). El aislante puede estar comprimido (no se utiliza en todos los modelos). Las manijas de la puerta pueden sobresalir del frente del lavavajillas, dependiendo del modelo. Dimensiones de la abertura del gabinete Las áreas sombreadas de las paredes del gabinete muestran dónde se pueden instalar las conexiones de servicio. Se puede reducir a 33 1/2 (851 mm) retirando las ruedas y la zona perforada del aislamiento (manta) en el lavavajillas. Mínimo, medido desde el punto más angosto de la abertura.