EXTERNAL VENTING PREPARATION
To prevent the build up of condensation produced by your DishDrawer™ Dishwasher, the external venting kit must be installed via one of the following options:
THROUGH SAME CABINET
THROUGH ADJACENT CABINET
THROUGH FLOOR
FRAMELESS
FRAMED
FRAMELESS
FRAMED
FRAMED & FRAMELESS
5
5
5
5
5
Ø57
Ø57
Ø57
Ø57
Ø57
200
25
200
200
200
100
100
25
100
100
custom framed edge
custom framed edge
ISO*
ISO*
ISO
z
z
A toe kick height of at least 100mm is required.
A Ø57mm service hole should be created through
the side wall following the guidance under ‘Cabinetry
preparation’. In addition to this, a second Ø57mm
service hole must be also be created through the
shelf and the base of the cavity to route the venting
hose through.
z
z
z
A toe kick height of at least 100mm is required.
A notched-out Ø57mm service hole should be
created through the side wall following the guidance
under ‘Cabinetry preparation’.
There is no minimum toe kick height for venting
the DishDrawer™ Dishwasher through the floor
below the cabinetry, the space below the floor
however, must be a sub-area of the house and have
adequate airflow.
z
z
Frameless cabinetry: A 100mm x 200mm cutout
must be created in the base of the adjacent cabinetry
to secure the duct to.
z
A Ø57mm service hole should be created through
the side wall following the guidance under ‘Cabinetry
preparation’. In addition to this, a Ø57mm service
hole must be also be created through the shelf, the
base of the cavity and the floor to route the venting
hose through.
z
z
Frameless cabinetry: A 100mm x 200mm cutout
must be created at the front of the cabinetry base to
secure the duct to.
Framed cabinetry: A toe kick depth of at least 60mm
is required. In addition, a 100mm x 200mm cutout
must be created within the adjacent cabinetry base
to secure the duct to. This cutout should be set
back a minimum of 25mm from the frame edge for
optimal venting.
Framed cabinetry: A toe kick depth of at least 60mm
is required. In addition, a 100mm x 200mm cutout
must be created within the adjacent cabinetry base
to secure the duct to. This cutout should be set
back a minimum of 25mm from the frame edge for
optimal venting.
z
z
The duct is not required for this venting method.
Ensure all cutout edges are smooth and rounded and
the supplied edge protector is fitted if required.
Ensure cutout in the floor is sealed adequately.
z
*Frameless install illustrated
*Frameless install illustrated
14
| General | Details |
|---|---|
| Name | FISHER AND PAYKEL DD60STX6I1 Dish Drawer Dishwasher |
| Make | FISHER and PAYKEL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.91 MB |

FISHER and PAYKEL DD60SCTX9 Dishwasher

FISHER and PAYKEL DD60DDFHX9 Dishwasher

FISHER and PAYKEL DD24SCTB9 N Dishwasher

FISHER and PAYKEL DD60SCTW9 Dishwasher

FISHER and PAYKEL DD60SDFTX9 Dishwasher

Fisher and Paykel DW24UT2I2 Dishwasher

FISHER AND PAYKEL DD60STX6I1 Dishwasher

FISHER AND PAYKEL DD24SHTI9N Dishwasher

FISHER AND PAYKEL DD60SDFHTX9 Tall Dishwasher

FISHER AND PAYKEL DD24DTI9 N Dishwasher