Home > Fisher & Paykel > Fisher Paykel DW60UT4I2 Built Under Dishwasher
Fisher Paykel DW60UT4I2 Built Under Dishwasher
| General | Details |
|---|---|
| Name | Fisher Paykel DW60UT4I2 Built Under Dishwasher |
| Make | Fisher & Paykel |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.19 MB |

FISHER PAYKEL DD24DCHTX9 N Dishwasher

FISHER PAYKEL DD24DCTW9N Dishwasher

FISHER PAYKEL DD24SCTX9 N Dishwasher

FISHER PAYKEL DD24DI9N Sanitize Dishwasher

FISHER PAYKEL DD24SV2T9N Sanitize Tall Dishwasher

FISHER PAYKEL DD60SCHX9 Dishwasher

FISHER PAYKEL DD60DAX9 Dishwasher

FISHER PAYKEL DD60SDFHTX9 Dishwasher

FISHER PAYKEL DW24UT4I2 Dishwasher

FISHER PAYKEL DD24SVT9 Dishwasher

Fisher Paykel DW60UT4I2 Built Under Dishwasher Overview
Summary of Contents
- Page 1: Built-under dishwasher installation guide for DW60UT4I2, DW60U4I2, and DW60U2I2 models.
- Page 2: Safety and warnings Electric shock hazard Cut hazard Failure to follow this advice may result in electrical shock or death. Failure to use caution could result in injury. Take care – panel edges are sharp. This appliance must be earthed. Improper connection of the equipment-earthing conductor can result in a risk of electric shock. Do not attempt to lift this product unassisted. Do not modify the power supply plug provided with the appliance.
- Page 3: Safety and warnings Installation must comply with your local building and electricity regulations. To reduce the risk of fire, injury to persons or damage when using the appliance, follow the important safety instructions listed below. Failure to install the custom panels correctly could invalidate any warranty or liability claims. At the completion of the dishwasher installation, the Installer must perform the Final Checklist. Do not repair or replace any part of the appliance unless specifically recommended in this guide. Ensure all water connections are turned off. The dishwasher must be installed to allow for future removal from the enclosure if service is required. This dishwasher is manufactured for indoor use only. Do not operate this appliance if it is damaged, malfunctioning, partially disassembled or has missing or broken parts. This appliance must be earthed.
- Page 4: Components required include various parts and tools necessary for installation. Keep all packing materials until the unit has been inspected. Inspect the product to ensure there is no shipping damage. Contact the dealer or retailer if any damage is detected. Fisher & Paykel is not responsible for shipping damage. Supplied tools include powered driver, cross-head screwdriver, and flat-head screwdriver. Additional supplied items include spacers, moisture protection tape, and a door panel template. Screws and brackets are also provided for installation. Quantity of screws may differ between models. Some items may not be required for specific models.
- Page 5: Product dimensions are provided for various models. Overall height ranges from 820 to 917 mm. Overall width varies between 521 and 857 mm. Overall depth is specified but not detailed. Height of chassis is included in the dimensions. Depth of chassis is mentioned without specific values. Height of feet may vary based on adjustment. Depth of toe kick recess is noted. Depth of inner door is specified as 33 mm. Height from top of chassis to bottom of inner door is listed as 683 or 719 mm.
- Page 6: Custom panel dimensions Maximum weight of door panels must not exceed 10kg (including handle). The panel should be adequately sealed to withstand moisture (50°C @ 80% RH). The back and sides of the panel should be completely sealed with a waterproof vapour barrier. Installation outside these specifications may result in condensation on cabinetry surfaces. Depending on the desired toe kick recess depth and door panel extension, the toe kick panel height may need to be adjusted. Minimum height of custom door panel for full coverage of the inner door is 714 mm. Minimum door panel width varies from 596 mm to 200 mm. Weight of door panel (including handle) ranges from 4 kg to 9 kg. Continuous toe kick installations are possible and detailed on page 15.
- Page 7: Cabinetry dimensions and clearances are important for installation. Connections can be located in an adjacent cabinet on either side of the dishwasher. Minimum clearance to adjacent cupboard door is specified. Minimum inside height, width, and overall depth are provided in millimeters. Minimum clearance to corner cupboard is noted. Height of toe kick area is indicated. Adjustments of leveling feet may affect minimum inside height. Overall depth includes door panels on adjacent cabinetry. Refer to 'Plumbing & electrical considerations' and 'Cabinetry preparation' for service requirements.
- Page 8: Plumbing and electrical considerations Your services can be installed to either the left-hand or right-hand side of the product in an adjacent cabinet. The drain hose should not extend more than 4m. A longer drain hose will cause reduced performance. The dishwasher should not be connected to a water system where there is no temperature control, unless the system is fitted with a suitable tempering valve. Maximum water temperature: 60°C. Ensure water connection complies with local plumbing regulations. Water pressure: 0.03-1MPa. Electrical requirements: 230 V, 50Hz, 10A. This dishwasher has anti-flood protection, which will stop the water flowing in the event of a leak within the machine.
- Page 9: Service access is important for maintenance. Locate the service holes on either side of the dishwasher. Ensure edges are smooth and rounded if holes are created through wood. Fit an edge protector if holes are created through metal. Maximum distance between rear of cavity and service hole is specified. Maximum distance between floor and service hole is dependent on levelling feet adjustment. Minimum diameter of service hole is indicated. Cabinetry depth of 580mm is referenced for service hole placement. Proper dimensions for service holes are crucial for installation. Adhering to these guidelines ensures effective service access.
- Page 10: Unpack product. Ensure all minimum cabinetry and service specifications have been met and that all services will be accessible after installation. Dispose of packaging responsibly. Ensure cabinetry floor is free from bumps and obstructions that could prevent the dishwasher from sliding into the cavity. Remove the install kit, any internal packaging, all rubber bands and all tape. Align the supplied moisture protection tape to the cabinetry as shown. Ensure this area is free of debris before carefully applying the tape to the surface.
- Page 11: Door panel preparation involves several key steps. Using a flat bladed screwdriver, raise the leveling feet, starting with the rear outside legs followed by the front legs. Ensure the door panel meets all specifications. Remove both screw covers before partially pushing the product into the cavity, pulling the hoses through to avoid damage. Using the template as a guide, pre-drill all holes into the panel. Check that the product sits level within the cavity. Ensure the sliding bracket is oriented correctly before securing it to the panel. If needed, adjust the rear middle leg from the front of the product using a 5mm Allen key. Select the desired spacer width, cut to size, and fit two spacers to each side of the product. Loosely fit both 16mm Philips hanging screws onto the door panel, ensuring a minimum space of 3 mm between the screw-head and the panel.
- Page 12: Secure door panel. Fit exit vent. Measure the custom panel overhang from the base of the inner door. Align the door panel to the product. Slot slider bracket and upper screws into place. Refer to the table below for the recommended cut location. Align door panel to surrounding cabinetry. Open door and secure panel to product using 4 x screws. On a protected surface, carefully cut the vent at the desired location. Slot the exit vent into the product and secure using two 3.5x11mm screws.
- Page 13: Balance door Use a 4mm Allen key to adjust the door tension. Rotate clockwise to increase tension, rotate counterclockwise to decrease tension. Loosely fit 2 x side fixing screws. Ensure both sides are adjusted evenly. Open the door at a 45° angle and ensure it holds. If the door does not stay open, repeat the above step. If needed, adjust the dishwasher within the cavity before tightly securing in place. Replace the screw covers. Secure to benchtop using 2 x screws if possible.
- Page 14: Install sound seal and toe kick. Fit sound seal. Mark the pilot hole locations for each bracket. Align both sound seal sheets to the base of the dishwasher. Measure the height of the lowest bracket hole against the toe kick panel. Ensure door swing is unobstructed before securing the seals. Ensure brackets are oriented correctly before fitting to the panel. Measure the toe kick depth. Align toe kick to product and ensure all door swing clearances have been met. Fit panel to surrounding cabinetry.
- Page 15: Plumbing & electrical connection Sink trap/waste tee installation Install the drain hose support to the back wall, as close to the underside of the countertop as possible. Refer to 'Plumbing & electrical considerations' for minimum install heights. Ensure hose is routed straight to the trap. Ensure the drain hose does not extend into water retained in the trap; an air gap is required to prevent waste water from siphoning back into the tub. Unplug or drill out the waste tee before securing joiner to sink trap or waste tee. Ensure the rubber washer is fitted when connecting the inlet hose to the tap. Hand-tighten into place. Using a spanner or pliers, turn a further 180° to secure, avoiding over-tightening. Do not turn water supply on; the dishwasher must be powered on for the flood protection feature to be enabled.
- Page 16: Installer checklist Check all parts are installed correctly and are secure. Turn power and water supply on and open the dishwasher. Ensure all packaging, tape and rubber bands have been removed. Ensure all clearance gaps have been maintained. Ensure the dishwasher is securely fastened to the cabinetry and door opens and closes freely. Check the spray arm is in place, mounted correctly and rotates freely. Ensure any knock-outs or plugs in the drain connection have been drilled out. The drain hose joiner must not support the weight of excess hose material. Ensure inlet hose has supplied rubber washer fitted, and that it is tightened. Ensure water supply is turned off until power is connected and turned on.