6-CLEAN-UP AND MAINTENANCE  
6.1 Periodical Maintenance and Clean-up  
Daily maintenance should be carried out by people informed about  
the safety instructions as following, after disconnecting power supply  
and water connections.  
6.1.1 Daily Maintenance:  
Daily maintenance should be carried by the user. In order to clean up  
the machine within the day following should be carried out  
periodically after the washing operation:  
1. Wash and rinse arms should be disconnected and the scraps  
remaining in those arms should be removed away using  
pressure water, brush, fine wire etc. and reinstalled back to  
their places.  
2. Scraps remaining in the washing tank should be removed and  
cleaned up. (Do not carry out washing operation without  
installing scrap filters)  
3. If the period between two washing operations exceeds “5  
Hours“ water outlet pipe should be disconnected and all of the  
water should be drained out fully.  
4. Suction filter should be disconnected and cleaned up with  
plenty of water.  
5. Inside of the tank should be cleaned up with a sponge or cloth  
and plenty of water.  
6. After cleaning operation is finished suction filter, water  
outlet pipe, scrap filters and washing and rinsing arms should  
be reinstalled.  
7. Scale formed on the carriers of the device after certain period  
of use, must be wiped away. If it is not cleaned up for a long  
time, scale formed on the carriers of the device, hinder the free  
movement of the hood.  
6.1.2 Periodical Maintenance:  
Periodic maintenance should be carried out by the user at least once  
in a month, after the cleanup and maintenance that must be  
conducted after each washing operation is completed. This should be  
done when the machine is ready for operation and before the dishes  
are set up in the machine. After ½ kg’s of decalcination substance is  
added to the washing tank, the machine is operated for ½ hours so  
that it cleans itself up. Afterwards the water within the machine is  
disposed and then refilled with fresh water. This time the machine is  
operated without any additive substance only with water for ½ hours  
and after the water inside is disposed, the machine will be ready for  
operation.  
If the device is not used for long period of time, you must drain the  
water left inside the boiler. For this purpose, let the water drain out  
after opening the tap (boiler tank tap) at the lower part of the devices  
body. Other wise, water staying inside too long, may harm the  
resistances.  
CAUTION!  
Never use cleaning chemicals containing bleaching agents, chlorine or hypochloride.  
Never use steel sponge or wire brush for cleaning purposes.  
Do not use pressurized water to clean inner and outer surfaces of the appliance.  
Before cleaning the interior of the dishwasher, first carefully remove from the boiler any parts that may cause  
injury during cleaning, such as sharp glass pieces.  
Wipe clean the interior of the dishwasher. Once wastes and particles are removed, re-place the  
washing/rinsing arms and filters.  
Clean the outer surface of the dishwasher with a damp cloth. Never use wet cloth for cleaning.  
After drying, clean with a stainless steel cleaning article.  
17  
GeneralDetails
Namemaxima HQ-400 Undercounter Dishwasher
Makemaxima
LanguageEnglish
FiletypePDF (Download)
File size0.5 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
maxima 09240000 Dishwasher
maxima 09240000 Dishwasher
maxima 09240080 Pass Through Dishwasher
maxima 09240080 Pass Through Dishwasher

maxima HQ-400 Undercounter Dishwasher