Miele PFD 101 Free Standing Dishwasher
| General | Details |
|---|---|
| Name | Miele PFD 101 Free Standing Dishwasher |
| Make | Miele |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.29 MB |

Miele PFD 103 SCi XXL XXL Dishwasher

Miele PFD 101 i Dishwasher

Miele AK-CC 550A APFD 102 Dishwasher

Miele PFD 102 APFD 102 Dishwasher

Miele 11 836 740 Dishwasher

Miele PFD 401 U Commercial Dishwasher

Miele PLW 8683 Laboratory Dishwasher

Miele PFD 100 SmartBiz Free-Standing Dishwasher

Miele 12 668 930 Dishwasher

Miele PFD 102 i Dishwasher

Miele PFD 101 Free Standing Dishwasher Overview
Summary of Contents
- Page 1: Installation plan PFD 101 PFD 101 i en - AU, NZ M.-Nr. 11 681 570
- Page 2: Installation notes Installation requirements Environmental requirements Electrical connection Water connection Appliance dimensions and installation dimensions Freestanding appliance/built-under appliance Connections on the back of the appliance Technical data Operating conditions
- Page 3: Installation notes for safe installation and commissioning of the dishwasher should be read. The installation plan includes dimensions, technical data, and site requirements for the dishwasher. The dishwasher must be installed and commissioned by qualified personnel. Installation should comply with valid regulations, standards, and health and safety codes. Furniture and fittings in the room must be suitable for the potential condensate. The supplied vapour barrier film protects the worktop from steam damage. Electrical connections must be performed by qualified personnel. The dishwasher should be connected via a suitably rated plug and socket or hard-wired with a disconnecting power switch. The connection cable must be protected from thermal damage. It is recommended to use a residual current device for increased safety.
- Page 4: Installation notes The dishwasher must only be connected to fully vented pipework. A brief increase in the water pressure can damage components of the dishwasher. The quality of the incoming water must correspond to the drinking water specification of the country in which the dishwasher is being operated. The dishwasher must be connected to the water supply in strict accordance with current local and national requirements. It can be connected to cold or hot water supplies. For short programme running times, dynamic water pressure of at least 200 kPa is also required. This appliance must be installed according to AS/NZS 3500.1 and AS/NZS 3500.2. The dual check valve supplied separately with this product must be installed between the tap and the water inlet hose. Turn on the tap gradually to test for leaks. The tap should remain accessible once the dishwasher has been installed so that the water supply can be shut off whenever the appliance is not in use.
- Page 5: Installation notes The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, it is recommended to connect the hose to a dual-chamber siphon. Use the hose clip supplied with the dishwasher if the hose is to be fitted directly to the drainage system on site. The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened to prevent blockage. Lay the drain hose so that it does not kink and is not subjected to pressure or tension. If the on-site drain connection is situated lower than the guide path for the lower basket rollers, a siphoning effect can occur. In this case, lay the drain hose with a bend so that its highest point is at least level with the guide path for the lower basket rollers. An external dispensing module for liquid cleaning agents can be connected to the back of the dishwasher. The dispensing module is available as an optional accessory and is supplied with installation instructions.
- Page 6: Appliance dimensions and installation dimensions Freestanding appliance/built-under appliance Front panel dimensions PFD 101 i Length Thickness Weight
- Page 7: Connections on the back of the appliance. On-site connections. Electrical connection. External dispensing, power supply connection. Equipotential bonding. Waste water. Cold or hot water. External dispensing, connection for dispensing hose sealed with a blind stopper. The dispenser connector is supplied with the dispensing module.
- Page 8: Connections External dispensing Max. delivery head Length of dispenser hose, DOS module to suction lance Length of dispenser hose, back of appliance to DOS module Length of power cable, back of appliance to DOS module Place the container on the floor next to the cleaning machine or in an adjacent cabinet. The container must not be placed on top of or above the cleaning machine.
- Page 9: Technical data Model: PFD 101, PFD 101 i Dimensions and weights Height: 845 mm, 805 mm Width: 600 mm, 1195 mm Depth: 600 mm Weight: 115 kg Max. floor load: 1000 N Sound power level: 46 dB(A) Sound pressure level in the workplace: 34.1 dB(A)
- Page 10: Technical data Electrical connection Standard electrical connection Voltage: AC 230V Frequency: 50 Hz Fuse rating: 15-16 A Power cable length: 1.7 m Power cable cross-section: 3x1.5 mm² Total rated load: 3.2 kW Max. water temperature: 60 °C Max. water hardness: 36 °dH
- Page 11: Technical data Max. water temperature: 82 °C Drain hose length: 1.5 m Max. drain hose length: 1 m Max. delivery head: 10 m Max. transient flow rate: 22 l/min Hose inner diameter: 22 mm Operating conditions: Ambient temperature +5 – +40 °C Relative humidity: Up to 31 °C, maximum 80% Max. altitude above sea level: 4000 m Storage and transportation conditions: Ambient temperature -20 – +60 °C
- Page 12: Page 12