INSTRUCTION MANUAL FOR DISHWASHERS  
SELF DIAGNOSTICS  
The machine is equipped with a self-diagnosis system that registers and warns of a number of  
malfunctions.  
Fault  
Description and possible remedies  
No rinsing. The rinsing cycle was not completed correctly. Make sure that the rinsing  
nozzles are clean.  
No drainage. The water was not drained or drained incorrectly. Check that the drain  
pipe is not bent or crushed and that the siphon and filters are not blocked. In machines  
fitted with an overflow pipe, remove this before starting the drainage cycle.  
Rinsing temperature reset fault. The boiler temperature did not reset in the set time  
during the washing cycle. Switch the machine off and then on and run a new cycle.  
Water filling in tank fault. Make sure the pipes are connected correctly, and that the  
water tap is open. Where foreseen, check the presence of the overflow. Switch the  
dishwasher off and then on and fill again.  
Tank thermometer fault. (Probe open) The machine does not read the tank  
temperature value. Switch the dishwasher off and then on.  
Tank thermometer fault. (Probe short circuited) The machine does not read the  
tank temperature value. Switch the dishwasher off and then on.  
Boiler thermometer fault. (Probe open) The machine does not read the boiler  
temperature value. Switch the dishwasher off and then on.  
Boiler thermometer fault. (Probe short circuited) The machine does not read the  
boiler temperature value. Switch the dishwasher off and then on.  
Boiler loading time out: boiler not filled. Impossible to carry out rinse cycle. Check  
that the water tap is open. Switch the dishwasher off and then on and run a new cycle.  
Insufficient rinse: the right amount of rinsing did not take place; make sure the rinse  
nozzles are clean. The error does not stop machine operation.  
Tank temperature reset fault: The tank temperature did not reset in the set time  
during the washing cycle. Switch the machine off and then on and run a new cycle.  
Electro-mechanical safety device: the boiler or tub safety thermostats have cut in, or  
the tub safety pressure switch has been triggered.  
Level safety switch: Incorrect water level in the tank.  
Dirty filter: incorrect water level in tank due to dirty filter or overflow fitted incorrectly.  
IMPORTANT: In the event service is required contact Rhima Service providing the fault code  
if possible.  
AUSTRALIA: 1300 347 944  
NEW ZEALAND: 0800 902 054  
SINGAPORE: +61 1300 347 944  
| 7  
GeneralDetails
Namerhima RU-40 Underbench Dishwasher
Makerhima
LanguageEnglish
FiletypePDF (Download)
File size0.55 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
rhima RU-50 Under Bench Dishwasher
rhima RU-50 Under Bench Dishwasher
rhima VU-35 Benchtop Glass or Dishwasher
rhima VU-35 Benchtop Glass or Dishwasher

rhima RU-40 Underbench Dishwasher