CAFE CDD220P2WS1 Smart Drawer Dishwasher
Installation Instructions
THERE ARE THREE DIFFERENT PLUMBING AND DRAINAGE OPTIONS - CHOOSE WHICH IS MOST SUITABLE
DRAINAGE OPTION 1 - Dishwasher and Ø 1-1/2” (38 mm) Standpipe
Screw Drain hose
support to back wall at
correct height.
If space is limited
Max.
4-3/4”
(120
for fixing, push
hose through drain
hose support
2
mm)
to required height.
IMPORTANT
1
Ensure that drain hose is installed
as close to the underside of the
countertop as possible. This will
ensure no waste re-enters the drain
hose in the event of poor flow or a
blockage in the plumbing.
1-1/2”
(38 mm)
Ensure the drain hose does not extend
into water retained in the trap; an air gap
is required to prevent waste water from
siphoning back into the tub.
NOTE: See,
the “CONNECT
INLET HOSE TO
HOT WATER”
step.
IMPORTANT
Ensure that drain connection
will comply with local plumbing
regulations.
Min. R 8”
(200 mm)
16