SYMPTOM  
POSSIBLE CAUSE  
ACTION  
Low incoming water  
temperature supplied to the  
Dishwasher  
Check out that incoming water temperature is at least  
120°F and pressure is at least 20 psi. Optimal incoming  
water temperature is 140°F and optimal incoming water  
pressure is 25 psi.  
Faulty thermostat (Tc)  
Verify that there is power on violet (vi) coming from Tc  
to Tt (only applies after Tc has been satisfied or >  
180°F). If A4 is displayed, reconnect temperature  
sensor. If A5 is displayed, replace temperature sensor.  
Verify voltage to t-stat. If voltage has been verified ok,  
check tank heater relay Ct  
Dishwasher RUNS.  
WASH WATER NOT  
REACHING REQUIRED  
TEMPERATURE OF 150°F  
Misadjusted/ faulty  
thermostat (Tt)  
Tank heater relay (Ct)  
faulty.  
Verify voltage at heater relay coil (A1, A2), solenoid  
closes when receiving voltage. If not, replace heater  
relay (Ct)  
Tank heater (Rt) faulty  
Door is closed  
Ohm out (between 10-12 Ohms) element check for  
continuity; if open, replace heater (Rt).  
Open the door and push the drain button  
for 3 sec.  
Overflow tube not  
removed.  
Open the door and remove the Front Right S/ S Filter and  
remove the overflow tube by inserting a finger through  
the hole on top of the overflow tube and pull upward.  
Drain pump (BD) clogged.  
Open drain pump cover and remove debris. (Lower front  
panel; unscrew white removable cover, rotate counter-  
clock wise  
Drain hose kinked  
Make sure the drain hose is not kinked and flush out any  
debris that may have been accumulated.  
Faulty Drain pump (BD)  
Verify voltage to drain pump; if receiving voltage,  
replace Drain pump (BD).  
Dishwasher Washes and  
Rinses but Does NOT DRAIN  
or overflows.  
Faulty safety pressure  
switch (P2), Overflow.  
Verify that the black rubber pressure tube is not kinked  
or damaged (air leak). If so, replace black rubber  
pressure tube. If not kinked or damaged, replace  
pressure switch P2.  
Machine temperatures or  
pressure may not be to  
specification.  
Wait until sanitized rinsing temperature reached a min.of  
180º F. Check out your incoming water temperature.  
Recommended incoming water temperature is 140°F and  
incoming water pressure is 20-25 psi.  
None or too little  
detergent being used.  
Make sure detergent to dish ratio is fallowed to  
manufacturer specification. Make sure that the detergent  
and rinse pumps have been adjusted and primed  
(priming only applies to the rinse pump). Check for kinks  
along the chemical lines. Make sure that the chemical  
line brass filters are completely submerged below the  
chemical level.  
Improper loading or  
overloading  
Read chapter on proper loading of dishwasher. Refer to  
page 15 of this manual.  
Washing and or rinsing  
arms jammed or dirty.  
Check that arms rotate properly by spinning them  
manually and that rinsing and washing nozzles are not  
blocked or dirty. Clean if necessary  
Clogged drain  
Remove obstruction from the pump and/ or make sure  
the drain hose is not kinked and flush out any debris that  
may have been accumulated.  
Dishes are not coming  
out clean enough.  
Machine not level  
Level machine by adjusting the unit’s legs accordingly.  
Refer to page 6 of this manual  
Excessive inlet pressure  
Install pressure reducing valve. Ensure flow is 20-25 psi.  
WATER OVERFLOW  
FROM BOTTOM OF THE  
DOOR  
Use ONLY commercial grade, low suds, liquid detergent  
for commercial appliances. Adjust the amount of  
chemicals being dispensed to the unit. Refer to page 14  
of this manual.  
EXCESS FOAM coming out  
of the door.  
Low water pressure, rinse  
aid container is empty, air in  
the pump and/ or lines.  
Verify that the min. incoming water pressure is 20 psi.  
Verify that there is enough rinse aid left in the container.  
Make sure that the rinse agent chemical lines are primed  
and free of kinks.  
Rinse agent not being  
dispensed  
Detergent tubes not  
placed properly inside  
container/ improper  
adjustment  
Verify detergent tubes are secured inside container  
Adjust chemicals to proper levels  
For Customer Service: Call 1866GO FAGOR – www.fagorcommercial.com |  
P. 17  
GeneralDetails
NameFAGOR AD-120CW Door Style Dishwasher
MakeFAGOR
LanguageEnglish
FiletypePDF (Download)
File size0.72 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
FAGOR 3LVF-421.1, 3LVF-421.1X Dishwasher
FAGOR 3LVF-421.1, 3LVF-421.1X Dishwasher
FAGOR 3LVF-423.1X Dishwasher
FAGOR 3LVF-423.1X Dishwasher

FAGOR AD-120CW Door Style Dishwasher