ggmgastro GLOZ50 Undercounter Dishwasher
4.5 Limits in Water Connection:
Water inlet temperature: 4-50°C.
Inlet pressure of flowing water:A rinsing pump is needed if pressure is 0-2 bars. A pressure of 2-4 bars is
appropriate. If pressure exceeds 4 bars, adjust the pressure using the pressure regulator.
If these conditions cannot be satisfied, appliance’s washing performance would decline.
4.6 Drain Connection:
4.6.1 Models Without a Drain Pump:
In models without a drain pump, waste water is transferred to the drain vent by gravity. Drain hose should run
to the drain vent with a downward slope. Therefore, drain vent height should be max. 30 mm. Never reduce
the diameter of the drain hose.
Allow a adequately long drain hose so that the appliance can safely be moved during servicing. Drain vent
diameter should be Ø42 mm (1 1/4ʺ) and drain should be below the hose outlet level. Make sure that the
hose-drain vent connection is watertight.
4.6.2 Models With a Drain Pump:
If drain vent is below the appliance’s drain outlet, attach the hose to the drain vent with a downward slope.
Otherwise, drain vent height should be 60 cm max. The Ø28 mm (3/4ʺ) drain vent should not be below the
appliance base.