Miele PFD 100 Smart Biz Free Standing Dishwasher
| General | Details |
|---|---|
| Name | Miele PFD 100 Smart Biz Free Standing Dishwasher |
| Make | Miele |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.3 MB |

Miele PFD 103 SCi XXL XXL Dishwasher

Miele PFD 101 i Dishwasher

Miele AK-CC 550A APFD 102 Dishwasher

Miele PFD 102 APFD 102 Dishwasher

Miele 11 836 740 Dishwasher

Miele PFD 401 U Commercial Dishwasher

Miele PLW 8683 Laboratory Dishwasher

Miele PFD 100 SmartBiz Free-Standing Dishwasher

Miele 12 668 930 Dishwasher

Miele PFD 102 i Dishwasher

Miele PFD 100 Smart Biz Free Standing Dishwasher Overview
Summary of Contents
- Page 1: Installation plan
- Page 2: Installation notes Installation requirements Environmental requirements Electrical connection Water connection Appliance dimensions and installation dimensions Freestanding appliance Built-in appliance/built-under appliance Technical data Operating conditions
- Page 3: Installation notes for the dishwasher should be read carefully, including the installation plan, service documentation, installation sheet, and operating instructions. The installation plan includes dimensions, technical data, and site requirements for the dishwasher. Only qualified personnel should install and commission the dishwasher, following valid regulations and safety codes. Furniture and fittings around the dishwasher must be suitable to handle condensate buildup. A vapour barrier film is provided to protect the worktop from steam damage when the door is opened. Electrical connections must be performed by qualified personnel, ensuring safety and compliance. The dishwasher should be connected via a socket or hard-wired with a power switch that can disconnect all poles. Accessibility to the socket and power switch must be maintained after installation, and an electrical safety test is required. The mains connection cable should be protected from thermal damage. It is recommended to use a residual current device (RCD) for increased safety, and equipotential bonding should be performed if possible.
- Page 4: Installation notes The dishwasher must only be connected to fully vented pipework. A brief increase in the water pressure can damage components of the dishwasher. The quality of the incoming water must correspond to the drinking water specification of the country. The dishwasher must be connected to the water supply in accordance with local and national water authority regulations. It can be connected to cold or hot water supplies. The dishwasher drain hose should be connected to a separate on-site drainage system. If a separate connection is not available, connect the hose to a dual-chamber siphon. Lay the drain hose so that it does not kink and is not subjected to pressure or tension. An external dispensing module for liquid cleaning agents can be connected to the back of the dishwasher. The dispensing module is available as an optional accessory and is supplied with installation instructions.
- Page 5: Appliance dimensions and installation dimensions Freestanding appliance Built-in appliance/built-under appliance Front panel dimensions PFD 101 i Length Thickness Weight
- Page 6: Connections on the back of the appliance include various on-site connections. Electrical connection is necessary for operation. External dispensing requires a power supply connection. Equipotential bonding is important for safety. Waste water management is essential. Cold or hot water connections are needed. There is an external dispensing connection for a dispensing hose sealed with a blind stopper. The dispenser connector is supplied with the dispensing module.
- Page 7: Connections External dispensing Max. delivery head Length of dispenser hose, DOS module to suction lance Length of dispenser hose, back of appliance to DOS module Length of power cable, back of appliance to DOS module Place the container on the floor next to the cleaning machine or in an adjacent cabinet. The container must not be placed on top of or above the cleaning machine.
- Page 8: Technical data Model Version Dimensions and weights Height Width Depth Weight Max. floor load Emission levels Sound power level
- Page 9: Technical data Standard electrical connection PFD 101 Voltage AC 230V Frequency 50 Hz Fuse rating 13 A Power cable length 1.7 m Power cable cross-section 3x1.5 mm² Heat output 1.9 kW Total rated load 2.1 kW Max. water temperature 60 °C Max. water hardness 36 °dH
- Page 10: Technical data Max. water temperature: 82 °C Drain hose length: 1.5 m Max. drain hose length: 1 m Max. delivery head: 10 m Max. transient flow rate: 22 l/min Hose inner diameter: 10 mm Operating conditions: Ambient temperature +5 – +40 °C Relative humidity: Up to 31 °C, maximum 80% Max. altitude above sea level: 4000 m Storage and transportation conditions: Ambient temperature -20 – +60 °C
- Page 11: Manufacturer: Miele & Cie. KG Alteration rights reserved / Publication date: 2023-12-04 M.-Nr. 11 673 200 / 04