Home > Miele > Miele PFD40x Built Under Fresh Water Dishwasher

Miele PFD40x Built Under Fresh Water Dishwasher

Installation plan  
PFD 400–PFD 407  
en - GB, AU, NZ  
M.-Nr. 11 935 780  
GeneralDetails
NameMiele PFD40x Built Under Fresh Water Dishwasher
MakeMiele
LanguageEnglish
FiletypePDF (Download)
File size0.48 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Miele PFD 103 SCi XXL XXL Dishwasher
Miele PFD 103 SCi XXL XXL Dishwasher
Miele PFD 101 i Dishwasher
Miele PFD 101 i Dishwasher
Miele AK-CC 550A APFD 102 Dishwasher
Miele AK-CC 550A APFD 102 Dishwasher
Miele PFD 102 APFD 102 Dishwasher
Miele PFD 102 APFD 102 Dishwasher
Miele 11 836 740 Dishwasher
Miele 11 836 740 Dishwasher
Miele PFD 401 U Commercial Dishwasher
Miele PFD 401 U Commercial Dishwasher
Miele PLW 8683 Laboratory Dishwasher
Miele PLW 8683 Laboratory Dishwasher
Miele PFD 100 SmartBiz Free-Standing Dishwasher
Miele PFD 100 SmartBiz Free-Standing Dishwasher
Miele 12 668 930 Dishwasher
Miele 12 668 930 Dishwasher
Miele PFD 102 i Dishwasher
Miele PFD 102 i Dishwasher

Miele PFD40x Built Under Fresh Water Dishwasher
Free PDF manual for the Miele PFD40x Built Under Fresh Water Dishwasher – with cycle guides, troubleshooting tips, and maintenance instructions 👉 View PDF online or download now and keep your dishwasher running flawlessly!

Miele PFD40x Built Under Fresh Water Dishwasher Overview

Summary of Contents

  • Page 1: Installation plan PFD 400–PFD 407 en - GB, AU, NZ
  • Page 2: Installation notes Installation requirements Environmental requirements Electrical connection Water connection Appliance dimensions Freestanding appliances Built-under appliances Technical data Operating conditions
  • Page 3: Installation notes for safe installation and commissioning of the dishwasher should be read, including the installation plan, service documentation, and operating instructions. The installation plan includes dimensions, technical data, and site requirements for the dishwasher. This dishwasher must be installed and commissioned by the Miele Customer Service Department, an authorized dealer, or a qualified specialist. Installation should comply with valid regulations, relevant standards, and health and safety codes. Condensate can build up around the dishwasher, so surrounding furniture and fittings must be suitable for purpose. A protective sheet is supplied to protect the worktop from steam damage when the door is opened. All electrical connection work must be performed by qualified personnel. The dishwasher should be connected via a socket or hard-wired with a power switch capable of disconnecting it at all poles. An electrical safety test must be conducted after installation and servicing. It is recommended to protect the dishwasher with a residual current device (RCD) type A with a trip current of 30 mA for increased safety.
  • Page 4: Installation notes The dishwasher must only be connected to fully vented pipework. A brief increase in the water pressure can damage components of the dishwasher. UK installation requirements include installing the double check valve supplied with the product between the stopcock and the water inlet hose. AU, NZ installation requirements specify that the dual check valve must be installed between the tap and the water inlet hose. Turn on the tap gradually to test for leaks. The quality of the incoming water must correspond to the drinking water specification of the country. The dishwasher must be connected to the water supply in accordance with local and national water authority regulations. The dishwasher can be connected to cold or hot water supplies. The stopcocks should remain accessible once the dishwasher has been installed.
  • Page 5: Installation notes The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, we recommend connecting the hose to a dual-chamber siphon. Use the hose clip supplied with the dishwasher if the hose is to be fitted directly to the drainage system on site. The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened to prevent blockage. Lay the drain hose so that it does not kink and is not subjected to pressure or tension. If the on-site drain connection is situated lower than the guide path for the lower basket rollers, a siphoning effect can occur. In this case, lay the drain hose with a bend so that its highest point is at least level with the guide path for the lower basket rollers. For AU, NZ the drain should be connected in accordance with AS/NZS 3500.2. Up to two dispensing systems for liquid cleaning agents and rinsing agents can be connected to the back of the dishwasher.
  • Page 6: Appliance dimensions Freestanding appliances The front of the plinth may vary depending on the model
  • Page 7: Appliance dimensions Built-under appliances The front of the plinth may vary depending on the model
  • Page 8: Appliance dimensions Built-under appliances PFD 404 U, PFD 407 U PFD 404 U DOS, PFD 407 U DOS
  • Page 9: Connections on the back of the appliance Waste water Electrical connection Hot water Cold water and cold water connection for steam condenser External dispensing, power supply connection Equipotential bonding External dispensing, connection for dispenser hose
  • Page 10: Connections On-site connections Waste water Electrical connection Hot water Cold water and cold water connection for steam condenser External dispensing, power supply connection Equipotential bonding External dispensing, connection for dispenser hose
  • Page 11: Connections External dispensing Max. delivery head Length of dispenser hose, DOS module to suction lance Length of dispenser hose, back of appliance to DOS module Length of power cable, back of appliance to DOS module Place the container on the floor next to the dishwasher or in an adjacent cabinet. The container must not be placed on top of or above the dishwasher.
  • Page 12: Technical data Electrical connection GB Option 1 Standard 3N AC 400 V Voltage variant AC 230 V Fuse rating 3 x 16 A Mains connection cable length 1.9 m Heater rating 8.5 kW Total rated load Option 2 Standard AC 230 V Fuse rating 16 A Mains connection cable length 1.9 m Heater rating 5.5 kW
  • Page 13: Technical data Electrical connection AU, NZ Standard 3N AC 400 V 50 Hz Voltage variant AC 230 V 50 Hz Fuse rating 3 x 16 A Mains connection cable length 1.9 m Mains connection cable cross-section 5 x 2.5 mm² Heater rating 8.5 kW Total rated load Option 2 Standard AC 230 V 50 Hz Mains connection cable cross-section 3 x 4 mm²
  • Page 14: Technical data Max. water temperature cold water: 20 °C Max. water temperature hot water: 60 °C Max. water hardness: 10.71 mmol/l Water connection pressure: 40-1000 kPa (cold water), 100–1000 kPa (hot water) Flow rate: 3 l/min Max. water temperature for drainage: 70 °C (PFD 400, PFD 401), 80 °C (PFD 402), 85 °C (PFD 404, PFD 405), 93 °C (PFD 407) Max. drain hose length: 4 m Max. delivery head: 1.5 m Integrated dispenser pump (DOS) max. delivery head: 1.5 m Length of dispenser hose, back of appliance to suction lance: approx. 1.8 m
  • Page 15: Technical data Dimensions Freestanding appliance Built-under appliance Height adjustment Width Depth Weights Max. floor load
  • Page 16: Technical data Emissions data Sound power level: 59 dB(A) re 1 pW Sound pressure level in the workplace Heat output into the room: 1.44 MJ/h Operating conditions: Ambient temperature +5 to +40 °C Relative humidity: Up to 31 °C, maximum 80 % Max. altitude above sea level up to 2000 m Storage and transportation conditions: Ambient temperature -20 to +75 °C Min. site access dimensions including transport pallet: Height 920 mm, Width 670 mm, Depth 740 mm Weights including packaging: PFD 400 - 85 kg, PFD 401 - 88.5 kg, PFD 402 - 80.5 kg, PFD 405 - 86.5 kg, PFD 404 - 86.5 kg, PFD 407 - 76.5 kg
  • Page 17: Page 17