8 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR THE TECHNICIAN)  
The dishwasher is able to identify a number of malfunctions and show them on the display. If the problem  
persists after the dishwasher has been switched off and back on, proceed as described below:  
Tank temperature probe  
malfunction  
Er 04  
Tank temperature probe disconnected or faulty.  
- The tank wasn’t filled in the expected time: check the water  
supply tap, the dynamic supply pressure, cleanliness of the inlet  
water filter, cleanliness of the rinse nozzles, any damage of the  
water charging hose. If the problem persists during filling:  
- Work level tank pressure switch damaged (it always detects  
“empty”: check if the tank safety pressure switch starts  
operating).  
Er 05 Tank water filling malfunction  
- Leakage from the tube connected to the air trap; if the problem  
is not solved, it occurs during the work program.  
- vent valve of the drain pipe obstructed with dirt: with  
siphonage, the tank gets completely empty at the end of a  
washing program.  
Check:  
- filter cleanliness; obstructions, bending and narrowing of the  
drain pipe.  
Water pump-out malfunction  
Er 06  
- possible obstructions of the drain pump (blocked with a foreign  
body).  
The problem might occur because water is continually entering  
the tank (the causes are as for “Er 05” – see above) If the boiler  
heating element is damaged, this might be due to operation with  
no water in the boiler - the pressure switch is indicating full even  
with the boiler empty: - damaged boiler heating element –  
contactor failure - open on boiler safety thermostat side. - boiler  
Boiler does not heat up as  
expected.  
Er 23  
temperature probe faulty or incorrectly positioned  
-
motherboard relay failure, Important: If the boiler heating  
element is damaged, this might be due to operation with no  
water in the boiler, pressure switch continues to give full reading  
even with boiler empty: check boiler air trap and/or relative  
pressure switch and replace if necessary.  
Boiler temperature probe  
malfunction  
Er 24  
Boiler temperature probe disconnected or faulty.  
The boiler wasn’t filled in the expected time: check the water  
supply tap, the dynamic supply pressure, cleanliness of the inlet  
water filter, any damage of the water charging hose, or check the  
following in this order:  
Boiler water filling  
Er 25  
malfunction  
- faulty boiler pressure switch (it always detects “empty”),  
- leakage or unbinding of the tube (water runs inside the tube)  
22  
GeneralDetails
NameNELSON AD60 Passthrough Dishwasher
MakeNELSON
LanguageEnglish
FiletypePDF (Download)
File size0.52 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
nelson AD40 Commercial Dishwasher
nelson AD40 Commercial Dishwasher

NELSON AD60 Passthrough Dishwasher