14 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR THE USER)
The dishwasher can show a series of malfunctions on display.
After the machine has been switched off and restarted, follow the steps below:
(IF THE PROBLEM PERSISTS, PLEASE CONTACT THE AFTER SALES SERVICE. PLEASE MAKE A NOTE OF THE
ERROR BEFORE CALLING)
Tank temperature probe anomaly
Tank water filling anomaly
Contact After-sales Service
Err04
Err05
Check that the water supply tap is open, the
dynamic supply pressure, cleanliness of the inlet
water filter.
Check that the filters are clean, and that the
drain pipe is not bent, obstructed, narrowed.
Check that the drain pump is not blocked.
Water pump-out anomaly
(water remains in the dishwasher)
Err06
Err09
Excessive water level in the tank
anomaly
Contact After-sales Service
Boiler heating anomaly (does not
heat)
Contact After-sales Service
Contact After-sales Service
Err23
Err24
Boiler temperature probe anomaly
Check that the water supply tap is open, the
dynamic supply pressure, cleanliness of the inlet
water filter.
Boiler water filling anomaly
Err25
Check that the nozzles of the rinsing spray arms
are not clogged.
Boiler emptying anomaly
Err26
Err27
Boiler emptying anomaly – with full
tank
Contact After-sales Service
19.390.7848.00
08/05/2020
36