Thermostop  
Set as “on” = minimum rinsing temperature as set, (see  
boiler temperature above) regardless of intake water  
temperature; the cycle duration may be a few seconds  
longer than the nominal length.  
Set as “off” = the minimum rinsing temperature might be a  
few degrees lower than the setting if hot intake water is not  
used.  
If the thermostop device is set “off” the rinsing °t are no longer monitored and the user is  
responsible for ensuring that the minimum correct °t are maintained for the tank and boiler. It is  
particularly important to check the intake water temperature.  
Also refer to the insufficient washing/drying /foam in tank point of the “troubleshooting” section :  
restore °t Stop ON and/or connect the appliance to a hot water supply.  
High speed (FST) or economy (ECO) filling (FILL)  
Fast start (FST): starts the dishwasher in less than the  
standard time; leads to higher water consumption for the  
first cycle start.  
Eco start (ECO): starts the dishwasher in standard time, with  
no added water consumption.  
On: enabled – OFF: disabled.  
Cycles performed counter  
Shows the count of the total cycles performed by the  
dishwasher since installation.  
This parameter cannot be modified or reset unless the  
software is reprogrammed.  
USER program duration customisation (optional, only if installed)  
USER. is the only program which can be customised.  
Scroll through the setup parameters to display USER.P1,  
P2….. followed by two dashes (e.g. P2--). Keep pressing the P  
button until USER appears followed by the duration  
(e.g. USER. 03.10).  
20  
GeneralDetails
NameNELSON AD60 Passthrough Dishwasher
MakeNELSON
LanguageEnglish
FiletypePDF (Download)
File size0.52 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
nelson AD40 Commercial Dishwasher
nelson AD40 Commercial Dishwasher

NELSON AD60 Passthrough Dishwasher