Installation Preparation
Prepare Electrical Wiring
WARNING
FOR PERSONAL SAFETY: Re-
move house fuse or open circuit
breaker before beginning instal-
lation. Do not use an extension
cord or adapter plug with this
appliance.
Electrical Requirements
•
This appliance must be supplied with 120V, 60 Hz., and
connected to an individual properly grounded branch
circuit, protected by a 15 or 20 ampere circuit breaker or
time delay fuse.
Cabinet Preparation & Wire Routing
The wiring may enter the opening from either side,
rear or the fl oor within the shaded area.
•
•
Wiring must be 2 wire with ground.
•
If the electrical supply does not meet the above require
ments, call a licensed electrician before proceeding.
•
Cut a 1-1/2” max. dia. hole to admit the electrical cable.
Grounding Instructions – Cable Direct
The hole must be free of sharp edges. If the cabinet wall
is metal, the hole edge must be covered with a bushing.
This appliance must be connected to a grounded metal,
•
Cable direct connections may pass through the same
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and be
connected to the equipment grounding terminal or lead
on the appliance.
hole as the drain hose and hot water line, if convenient. If
cabinet wall is metal, the hole edge must be covered with a
bushing. NOTE: Power cords with plug must pass through
a separate hole.
Grounding Instructions – Power Cord Models
This appliance must be grounded. In the event of a mal-
function or breakdown, grounding will reduce the risk of
electrical shock by providing a path of least resistance for
electric current. The plug must be plugged into an appro-
priate outlet that is installed and grounded in accordance
with local codes and ordinances.
Electrical Connection to Dishwasher
Electrical connection is on the right front of dishwasher.
•
For cable direct connections the cable must be routed
as shown in Figure E. Cable must extend a minimum of 24”
from the rear wall.
•
For power cord connections, install a 3-prong grounding
type receptacle. The power-supply receptacle for the
appliance shall be installed in a cabinet or on a wall
adjacent to the undercounter space in which the
appliance is to be installed.
WARNING
The improper connection of the
equipment grounding conductor
can result in a risk of electric
shock. Check with a qualifi ed
electrician or service represen-
tative if you are in doubt that the
appliance is properly grounded.