MEIKO UPster U 400 M2 Glass and Dishwasher
Power cable/fixed connection:
Recommended connection with protective equipotential bonding
The machine and accessory appliances are intended for permanent connection to
the locally available power supply and the locally available protective equipotential
bonding and have been tested accordingly before being brought to market.
A 5-pole terminal strip (L1, L2, L3, N, PE) must be used for connection to a three-
phase current.
Electricity supply without a neutral wire (N): When connecting to three-phase cur-
rent, use a 4-pole clamping strip (L1, L2, L3, PE).
Wire colours: live wire L1 = black/1, L2 = brown/2, L3 = grey/3, neutral wire N =
blue/4, protective earth conductor PE = green-yellow
Alternative connection without protective equipotential bonding
The operator can decide at his/her own discretion and under his/her own responsi-
bility to connect the electrical supply using customer resources in collaboration with
a professional electrician:
1. Fixed connection without protective equipotential bonding
2. Plug connection according to EN 60309 (CEE plug connection)
Note
Where discharge currents exceed 10 mA, the use of an RCD/FI is not recom-
mended. False alarms restrict machine availability.
MEIKO expressly excludes any liability for damages caused by improper connection
of the machine.
This includes any work in connection with services due to said connection, e.g. pro-
cessing complaints or claims due to:
•
•
Triggered RCD/FI
Automatic shut-down of the supply when consistency is lost in the protective
earth conductor (EN 60204-1 Chap. 8.2.8.c)
Local main switch
Install a main switch with all-pole disconnection from the mains in accordance with
the installer's regulations in the permanently installed on-site installation. The main
switch must be easily accessible for the operating personnel. The contact opening
width must correspond to overvoltage category III in each pole. Refer to the circuit
diagram or the data sheet of the main switch for technical data such as torque and
stripping length.
If an unearthed neutral conductor (N) is used with three-phase current, a power dis-
connection device with 4 poles (with alternating current 2 poles) must be used.
Local fuse protection
Fuse the machine for the rated current shown on the rating plate. Fuse the electrical
connection as a separately fused circuit (final circuit). Take note of the connection
variants.
Protective equipotential bonding
The screw for the potential equalisation
is located on the back of the machine
near the media connections.
9760441
19 / 48