Home > MEIKO > MEIKO UPster U 400 M2 Glass and Dishwasher

MEIKO UPster U 400 M2 Glass and Dishwasher

Mainte-  
nance re-  
quirement  
Maintenance work  
Visual check  
7.  
Rinse aid dosing  
Replace peristaltic hose  
annually  
annually  
Check rinse aid dosing system is working and not leaking  
8.  
Test run with functional test of whole machine  
Check filling and heating until it is ready for operation  
Visual inspection of the entire machine for leaks  
Check sample rinsing and rinsing results  
annually  
annually  
annually  
9.  
Fresh water  
10. Electrical safety check (certificate is optional)  
Water quality, temperature  
°C  
°dH  
°KH  
µS/cm  
annually  
Visual inspection  
annually  
annually  
annually  
annually  
Check earth wire  
Measure insulation resistance  
Measure current on protective earth conductor  
9.3  
Daily cleaning  
Caution  
Material damage due to water ingress  
Electrical cables and electronic components can be damaged if they come into  
contact with water.  
•
The dishwashing machine, switch cabinets and other electrical components  
must never be sprayed with a hose or high pressure cleaner.  
•
•
Make sure that no water can enter the machine unintentionally.  
If installed at ground level, never flood the surrounding room.  
Note  
Do not use a foaming detergent for dish-washing by hand for pre-cleaning or clean-  
ing the dishwasher. Foam causes malfunctions and results in poor wash results.  
The machine is emptied, see chapter “Shutting down the dishwasher” on page 27.  
1. Open door.  
40 / 48  
9760441  
 
GeneralDetails
NameMEIKO UPster U 400 M2 Glass and Dishwasher
MakeMEIKO
LanguageEnglish
FiletypePDF (Download)
File size0.68 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Meiko FV 40.2 Glass and Dishwasher
Meiko FV 40.2 Glass and Dishwasher

MEIKO UPster U 400 M2 Glass and Dishwasher