MEIKO UPster U 400 M2 Glass and Dishwasher
8.9.3 Replace counter for partial desalination cartridge (optional)
For dishwashers with a partial desalination cartridge and activated end-of-service
indicator, the counter must be reset after changing the partial desalination car-
tridge.
2. To reset the counter, select entry 1-5.
3. Confirm the selection to reset the value.
The setting level can be departed with the on/off key.
8.10 Dosing system level
1. Switch to authorisation level 4, Dosing technology level (40000 or 40044), see
page 33.
The parameters relevant for the dosing technology are displayed and can be
changed.
Code display Meaning
Adjusting range
0.10 - 1.00 ml/L
P104
P105
P218
P219
Rinse aid dosing quantity
Detergent dosing quantity
Lack of rinse aid
0.10 - 20.00 ml/L
1/0 = Display on/off
1/0 = Display on/off
Lack of detergent
0 = Do not activate
Rinse aid dosing unit activation
method
1 = Activate through calculated running time
2 = Activate as per pressure booster pump
3 = Activate as per wash pump
P224
P225
0 = Do not activate
Detergent dosing unit activation
method
1 = Activate through calculated running time
2 = Activate as per pressure booster pump
3 = Activate as per wash pump
P321
P322
P326
P327
Rinse aid dosing unit output
Detergent dosing unit output
Rinse pipe bleed time
0.10 - 10 L/h
0.10 - 20 L/h
0 - 255 s
Detergent pipe bleed time
0 - 100 s
36 / 48
9760441
| General | Details |
|---|---|
| Name | MEIKO UPster U 400 M2 Glass and Dishwasher |
| Make | MEIKO |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.68 MB |