8.9.3 Replace counter for partial desalination cartridge (optional)  
For dishwashers with a partial desalination cartridge and activated end-of-service  
indicator, the counter must be reset after changing the partial desalination car-  
tridge.  
1. Switch to authorisation level 1 Service level (10001), see page 33.  
2. To reset the counter, select entry 1-5.  
3. Confirm the selection to reset the value.  
The setting level can be departed with the on/off key.  
8.10 Dosing system level  
1. Switch to authorisation level 4, Dosing technology level (40000 or 40044), see  
page 33.  
The parameters relevant for the dosing technology are displayed and can be  
changed.  
Code display Meaning  
Adjusting range  
0.10 - 1.00 ml/L  
P104  
P105  
P218  
P219  
Rinse aid dosing quantity  
Detergent dosing quantity  
Lack of rinse aid  
0.10 - 20.00 ml/L  
1/0 = Display on/off  
1/0 = Display on/off  
Lack of detergent  
0 = Do not activate  
Rinse aid dosing unit activation  
method  
1 = Activate through calculated running time  
2 = Activate as per pressure booster pump  
3 = Activate as per wash pump  
P224  
P225  
0 = Do not activate  
Detergent dosing unit activation  
method  
1 = Activate through calculated running time  
2 = Activate as per pressure booster pump  
3 = Activate as per wash pump  
P321  
P322  
P326  
P327  
Rinse aid dosing unit output  
Detergent dosing unit output  
Rinse pipe bleed time  
0.10 - 10 L/h  
0.10 - 20 L/h  
0 - 255 s  
Detergent pipe bleed time  
0 - 100 s  
36 / 48  
9760441  
   
GeneralDetails
NameMEIKO UPster U 400 M2 Glass and Dishwasher
MakeMEIKO
LanguageEnglish
FiletypePDF (Download)
File size0.68 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Meiko FV 40.2 Glass and Dishwasher
Meiko FV 40.2 Glass and Dishwasher

MEIKO UPster U 400 M2 Glass and Dishwasher