MEIKO UPster U 400 M2 Glass and Dishwasher
INFO Description
Possible cause
Measures/remedial action
•
•
Possible to continue work at lim-
ited capacity
•
•
No boiler/tank heating
No fresh water supply
Emergency pro-
120
gramme active
Call a service technician!
•
•
•
•
Door/hood open
I/O circuit board defective
Microswitch defective
Microswitch not correctly set
•
•
Close door/hood
121 Door/hood not closed
Call a service technician!
Incorrect password/no
authorisation
122
•
Code incorrectly entered
•
•
Enter code again
No intervention by the operator is
necessary
Factory setting param-
eter list
123
•
•
Switch supply voltage on/off
•
Message disappears after 5 min.
The set operating hours
(P 122) or batch number
(P 123) has been reached
•
•
Possible to continue working
Call a service technician!
Maintenance neces-
sary
126
Lack of rinse aid (with
420 integrated fill-level de-
tection)
•
•
•
Replace empty canister
Check suction lance
•
•
Canister empty
Suction lance not correctly
introduced
Lack of detergent (with
520 integrated fill-level de-
tection)
Where appropriate, ventilate
pipes
•
•
•
Let regeneration programme run
to completion
•
•
Regeneration programme
has been started and is run-
ning
Regeneration is run-
ning
720
Regeneration programme cannot
be interrupted
Possible to continue working
Regeneration not pos-
sible
721
Salt container empty
Fill salt container
Fill salt container
•
•
No salt present
722 Salt container empty
•
Where appropriate, Fill water in
the salt container
No water in the salt container
ERR
Description
Possible cause
Measures / remedial action
•
EEPROM
•
•
•
Not possible to continue
working
–
–
–
Not present/defective
001
EEPROM error
Installed incorrectly
Incorrect data/empty
Call a service technician!
Not possible to continue
working
111
Floor pan leakage
•
•
There is a leak
•
•
Call a service technician!
Not possible to continue
working
Signal of the two door contact
switches unequal
Malfunction/defect door contact
switch
118
201
•
Call a service technician!
Boiler level not reached during
first filling (with integrated pres-
sure booster pump)
•
•
Fresh water inlet insufficient (wa-
ter tap closed)
•
•
•
Check water supply
Check feed hose
Feed hose kinked/discon-
nected/leaks
Check pre-filter/sieve and
clean, if necessary
Boiler level not reached on time
during filling (with integrated
pressure booster pump)
•
•
•
Inlet filter soiled
202
•
Where appropriate, call a
service technician!
Solenoid valve defective
Boiler switch defective
9760441