Pressure range of the fresh water supply flow pressure upstream of the solenoid valve:  
Machines with air gap or pressure booster pump:  
60 500 kPa (0.6 5 bar)  
Machines with a safety device to prevent backflow:  
250 500 kPa (2.5 5 bar)  
Maximum pressure  
Do not exceed maximum pressure of 500 kPa (5 bar).  
Measures to ensure correct water pressure:  
If the minimum flow pressure is too low, increase the pressure using a pressure  
booster pump.  
If the maximum pressure is exceeded, limit the pressure using a pressure regu-  
lator.  
Other measures:  
Ensure that no foreign iron particles can enter the appliance via the fresh water  
connection. The same also applies for contamination by other metal particles  
(e.g. copper shavings). Corresponding instructions are contained in the assem-  
bly plan.  
A dirt trap must be fitted in the fresh water supply to protect the solenoid valve.  
After the dishwashing machine has been unused for longer periods of time,  
drain the connection line and wash it before placing the machine in operation  
again.  
When replacing an old machine with a new one, make sure that the existing  
feed hose is exchanged for the new feed hose supplied with the machine.  
6.1.5 Requirements to the electrical connection  
Warning  
Danger to life from electric shock  
Contact with live electrical parts can lead to serious injury or death.  
Work at or repairs to the electrical system must be conducted by a qualified  
electrician who complies with the electrotechnical rules.  
Disconnect the machine from the power supply before working on the electrical  
system. To do this, turn the local mains switch to OFF and ensure that it can't  
be switched back on again.  
Note  
The wiring diagram is located behind the front panel of the dishwashing machine.  
This must remain in the machine!  
The type plate with the electrical connected values is located inside the front panel.  
Other dangers  
Danger of death by electric shock: contact with live electrical parts can lead to seri-  
ous injury or death.  
Who may connect it?  
Local earth wire system  
The machine must be connected by a (MEIKO authorised) qualified electrician in  
accordance with the locally applicable standards and regulations.  
The electrical safety of this machine is only ensured if it is connected to a properly  
installed protective conductor system. It is very important to verify this fundamental  
safety feature. If in doubt, have the building wiring checked by an electrician.  
Voltage and frequency  
The machine may only be operated with the data provided on the rating plate (see  
page 14). Take note of the available connection variants.  
18 / 48  
9760441  
 
GeneralDetails
NameMEIKO UPster U 400 M2 Glass and Dishwasher