Home > MEIKO > MEIKO UPster U 400 M2 Glass and Dishwasher

MEIKO UPster U 400 M2 Glass and Dishwasher

ERR  
Description  
Possible cause  
Measures / remedial action  
No change detected by the  
boiler level switch when empty-  
ing (with integrated pressure  
booster pump)  
•
•
Pressure booster pump defective  
Plug connections disconnected  
(e.g. pressure booster pump)  
203  
•
•
•
Start capacitor defective  
•
•
Not possible to continue  
working  
Boiler level switch defective  
No change yet detected at the  
boiler level switch (with inte-  
grated pressure booster pump  
installed) after the rinse time ex-  
pired  
No signal to or from pressure  
booster pump and I/O circuit  
board  
Call a service technician!  
204  
•
No signal boiler full - from I/O cir-  
cuit board  
•
•
•
Boiler heating defective/melting  
beads, heating element  
Temperature sensor defective, in-  
correct installation position  
•
•
Not possible to continue  
working  
Boiler temperature not reached  
after max. heat time (P310)  
205  
Boiler protection defective, output  
switch triggered  
Call a service technician!  
•
•
No signal from I/O circuit board  
Boiler not ready for final rinse on  
time (temperature or level not  
reached)  
•
•
•
Acknowledge message, con-  
tinued work possible  
•
Boiler heating defective (melting  
beads)  
Let programme run without  
intervention by the operator  
206  
Wash time increase  
•
•
Temperature sensor defective  
If it occurs frequently, call a  
service technician!  
Boiler protection defective, output  
switch triggered  
•
No signal from I/O circuit board  
Boiler temperature sensor short-  
circuit  
•
•
•
Sensor defective  
210  
211  
•
•
•
•
Not possible to continue  
working  
Sensor position not correct  
Boiler temperature sensor inter-  
ruption  
Plug contact not connected  
properly  
Call a service technician!  
Not possible to continue  
working  
•
•
Contactor sticking  
“Actual” boiler temperature too  
high (>95°C)  
212  
Incorrect sensor/defective sensor  
Call a service technician!  
•
•
•
•
•
•
Feeding water pressure too low  
Inlet filter soiled  
•
•
•
•
•
Check water supply  
Check feed hose  
Number of circulatory pumping  
cycles for tank filling exceeded  
Rinse nozzles dirty  
Air trap dirty  
301  
Clean inlet filter  
Tank level analysis disrupted  
Clean rinse nozzles  
Call a service technician!  
Condensate in level pipe  
Feed hose kinked/discon-  
nected/leaks  
While drain pumping during the  
wash programme, tank level 1 is  
not fallen below on time (with in-  
tegrated drain pump)  
•
•
•
•
•
•
•
•
Drain pump output too low  
Drain pump dirty/defective  
Impeller loose  
302  
303  
•
•
Not possible to continue  
working  
Drain pump plug connection open  
Start capacitor defective  
Call a service technician!  
Tank level analysis disrupted  
Aquastop does not close correctly  
No signal from I/O circuit board  
While drain pumping during the  
wash programme, tank level 3 is  
not fallen below on time (with in-  
tegrated drain pump)  
32 / 48  
9760441  
GeneralDetails
NameMEIKO UPster U 400 M2 Glass and Dishwasher
MakeMEIKO
LanguageEnglish
FiletypePDF (Download)
File size0.68 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Meiko FV 40.2 Glass and Dishwasher
Meiko FV 40.2 Glass and Dishwasher

MEIKO UPster U 400 M2 Glass and Dishwasher