nelson AD40 Commercial Dishwasher
- leakage or unbinding of the tube (water runs inside the tube)
- menu service wrong setting “rP”
- check cleanliness of the rinse nozzles
- faulty boiler pressure switch (it always detects “full”)
- leakage or unbinding of the tube (water runs inside the tube)
- rinsing pump malfunction (if present)
Er 26 Boiler emptying malfunction
Faulty boiler pressure switch (it always detects “full”). If this
occurs in models without rinsing pump, the boiler pressure
switch is wrongly detected: check settings in the service menu on
entry “rP”
Boiler emptying malfunction –
with tank full
Er 27 Or boiler full signal on models
without rinsing pump
“rp” = on for models with rinsing pump
“rp” = of for models without rinsing pump