Home > CMA > CMA-66 EST-66 Conveyor Dishwasher

CMA-66 EST-66 Conveyor Dishwasher

Getting Started  
2.3.1. Electrical*  
A 3-phase 208-240 volt AC, 60 Hz dedicated circuit should be used to supply electrical energy to  
the CMA-66 dishwasher (see specification sheet page 2). Connect the wire that has the highest  
voltage (stinger lead) to the main contactor’s power terminal L2. Power lead wires (L1, L2 and L3)  
used for the CMA-66 at installation must comply with all local and State electrical codes.  
2.3.2. Plumbing*  
The water supply connection is made with a ½” hot water line to the water supply inlet on the top  
of the machine. The water supplied to the machine must be a minimum of 140° F for the CMA-  
66L and a minimum of 180° F for the CMA-66H.  
NOTE: The High Temp machine (CMA-66H) comes with two water supply line connections. One  
is for the final rinse at 180° F and the other is to fill the machine—this water will be  
heated to the appropriate temperature by the wash tank heater. (See specification sheet  
on page 2).  
There are two 2” drain connections to be made. One connection is made at either end of the  
horizontal drainpipe coming from the wash tank and the other connection is made at the scrap  
tray drain. (Instructions for installing the scrap tray assembly are provided in section 2.3.4 Scrap  
Tray Assembly and Overflow Chute Installation.) One of the ends of the horizontal drainpipe has a  
cap on it – simply move the cap to the other end if it’s currently on the end needed for the drain  
connection.  
2.3.3. Installation Notes  
1. Tables must slant into the machine for proper drainage (for each 28" of table length  
a drop of at least ¾” in table height is recommended). See Figure 2.3.3a.  
FRESH WATER  
PREWASH  
WASH/RINSE  
TO SCRAP  
ACCUMULATOR  
DISH FLOW  
Figure 2.3.3a  
See also installation instructions on new style CMA-66 conveyor (Section 4.  
Customer Notice)  
2. The scrap tray assembly is placed inside the machine for shipping. Follow the  
instructions provided in section 2.3.4 Scrap Tray Assembly and Overflow Chute  
Installation to properly attach the scrap tray assembly to the dishmachine.  
3. Figure 2.3.3b shows the different settings available on the conveyor cam.  
* Electrical and plumbing connections must be made by a qualified person who will comply with all  
available Federal, State, and Local Health, Electrical, Plumbing and Safety codes  
MODEL CMA-66 Installation & Operation Manual Rev. 1.09 B  
Page  
6
GeneralDetails
NameCMA-66 EST-66 Conveyor Dishwasher
MakeCMA
LanguageEnglish
FiletypePDF (Download)
File size0.59 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
CMA UC65e M3 Undercounter Dishwasher
CMA UC65e M3 Undercounter Dishwasher
CMA H-1X Undercounter Dishwasher
CMA H-1X Undercounter Dishwasher
CMA EST-FL1 EST Front Loader Water Dishwasher
CMA EST-FL1 EST Front Loader Water Dishwasher

CMA-66 EST-66 Conveyor Dishwasher