Operation  
Note: If at any time less than a full Auto Fill cycle is desired with the IDEC brand  
timer, the Auto-Fill can be interrupted (stopped) by turning off the power to the  
machine. The machine will resume normal operation upon restoring power without  
continuing the Auto Fill cycle.  
3.1.3. Rinse Pressure Regulator  
The CMA-66 requires a supply water pressure of 24 PSI minimum. The pressure is  
then reduced by the supply water regulator. Use the following procedure to adjust  
the rinse pressure to 20 PSI:  
1. Close the door on the machine.  
2. Turn the Power switch to the "ON" position.  
3. Using a rod or something long to avoid contact with the rinse water, actuate  
the final rinse trip switch—this activates the water solenoid. With the rinse  
water flowing adjust the pressure regulator until the gauge reads 20 PSI.  
Adjustment tip: Always adjust “down” when setting this pressure regulator. In  
other words—intentionally raise the pressure above the desired set point and  
then carefully bring it down to the correct pressure.  
3.1.4. Wash Tank Temperature  
The wash tank temperature for the CMA-66 is set at the factory. Should you ever  
find a need to adjust it—after replacement of the thermostat for example—simply  
perform steps 1 through 4 in section 3.2 Beginning Operation.  
MODEL CMA-66 Installation & Operation Manual Rev. 1.09 B  
Page  
15  
GeneralDetails
NameCMA-66 EST-66 Conveyor Dishwasher
MakeCMA
LanguageEnglish
FiletypePDF (Download)
File size0.59 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
CMA UC65e M3 Undercounter Dishwasher
CMA UC65e M3 Undercounter Dishwasher
CMA H-1X Undercounter Dishwasher
CMA H-1X Undercounter Dishwasher
CMA EST-FL1 EST Front Loader Water Dishwasher
CMA EST-FL1 EST Front Loader Water Dishwasher

CMA-66 EST-66 Conveyor Dishwasher