Controls and Operation  
DIVERTER VALVE  
UIM AND TUB LIGHT BEHAVIOR  
UIM lighting and tub lighting operation are synchronized.  
The diverter valve helps control water flow depending on  
the selected wash cycle.  
When the UIM lighting turns on, the rate that the UIM  
lights increase their brightness matches the rate that  
the tub lights increase their brightness so that both  
lighting systems match.  
The diverter valve manages water flow between the lower,  
middle, and upper wash arms. It uses a high-torque motor  
to drive a disc valve via a gear box. A proximity sensor  
sends information on the disc position to the MCM. The  
diverter valve distributes water from the wash pump to the  
upper/middle and lower spray arms at different pressures.  
In select cycles, it alternates flow between the arms to  
deliver a "soak and scrub" action.  
When the door is closed, the tub lights instantly turn  
off.  
When the door is opened, the tub lights slowly  
increase their brightness to 100% output level in 3  
seconds.  
When it diverts water to the upper/middle and lower  
arms separately, the unit also adjusts the wash pump  
RPMs to help maintain the pressure.  
If the door is left open at an angle for 10 minutes, the  
tub lights dim slowly to a 20% output level. Then, if  
the user leaves the door open at any angle for  
another 5 minutes, the tub lights turn off. If the door  
moves during this 15-minute period, the tub lighting  
dimming sequence starts over.  
Quick and Rinse & Hold cycles do not divert water.  
All other cycles use the diverter valve.  
WATER INLET VALVE  
When Standby Power mode automatically turns on, all  
lighting dims as above.  
When the water inlet valve (SOL1) is operated manually in  
Service mode, it will fill the unit with 1.0 gallons of water  
before automatically turning off.  
Dishwasher lighting control does not affect or control  
lighting on the Sub-Zero Group Owner's App.  
The water inlet valve cannot fill the unit to the point that  
water overflows out of the unit. The water level is  
monitored by the pressure sensor. When the pressure  
sensor reaches a predetermined value, the MCM turns on  
the drain pump.  
TEMPERATURE AND TURBIDITY SENSOR  
The temperature and turbidity sensor (AE1) is a  
combination sensor.  
The temperature sensor portion is an integrated NTC  
thermistor. The temperature sensor will sense  
incoming water temperature as soon as the level of  
water in the sump rises to cover it.  
The turbidity sensor uses infrared light to measure  
how dirty the water in the sump is. This helps to  
determine the rate of cleaning of the load.  
The dishwasher's UIM has no means to show temperature  
or turbidity. Monitoring either of these requires the  
Connected Diagnostics Program.  
828019 REV B 08/2023  
4
GeneralDetails
NameCOVE DW2450 Dishwasher
MakeCove
LanguageEnglish
FiletypePDF (Download)
File size0.71 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
COVE DW2451 Dishwasher
COVE DW2451 Dishwasher
COVE DW2451-ADA Dishwasher
COVE DW2451-ADA Dishwasher
COVE DW2450, DW2450WS Dishwasher
COVE DW2450, DW2450WS Dishwasher
DW2450 Cove Dishwasher
DW2450 Cove Dishwasher

COVE DW2450 Dishwasher