Meiko FV 40.2 Glass and Dishwasher
Model
F
V
40.2/40.2G
ERR Description
Possible cause
Measures/remedy
Air gap dirty
Condensate in level pipe
306 exceeded. Tank level Level sensor defective
Drain dishwasher
and refill
Call service
technician
Max. tank level
analysis disrupted
Plug contact not connected
properly
Connector loose
Sensor or I/O circuit board
defective
Tank level sensor
defective
Call service
technician
307
Short-circuit of
temperature sensor
Sensor defective
310
311
Sensor position not correct
Plug contact not connected
properly
Further operation not
possible
Interruption of
temperature sensor
Call service
technician
Actual tank
Contactor contact sticking
312 temperature too high Incorrect sensor/defective
(>85°C) sensor
Please contact your authorized MEIKO customer service if:
•
•
•
There is an issue with the dishwasher, but no error code is displayed, OR
An error code is displayed that is not listed here, OR
The listed measures cannot solve the problem.
For a list of authorized customer service points, please either scan the QR code
on the back cover of these operating instructions, visit our website at
10.6 Modifying the settings
Key
Meaning
Key
Meaning
STOP key
START key
•
Starts programming
•
Confirms entry and
jumps to next position
in the code
Program key 1
Program key 2
•
Increases value by one
•
Decreases value by
one
1. Press the STOP key for approx. 5
seconds until CodE 1- - - - - is
displayed.
9020132
47 / 64
| General | Details |
|---|---|
| Name | Meiko FV 40.2 Glass and Dishwasher |
| Make | MEIKO |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.59 MB |

MEIKO UPster U 400 M2 Glass and Dishwasher