ERR Description
pressure booster
Possible cause
Measures/remedy
booster pump) loose
Call service
pump integrated)
Starting capacitor defective technician
Boiler level switch defective
No signal for pressure
booster pump on - from I/O
circuit board
No change yet
detected at boiler
level switch (with
pressure booster
pump integrated) after
rinse time expired
204
No signal for boiler full -
from I/O circuit board
Boiler heating
defective/welding beads on
heater
Temperature sensor
defective, incorrect
mounting position
Boiler contactor defective,
circuit breaker triggered
No signal from I/O circuit
board
Further operation not
possible
Call service
technician
Boiler temperature not
205 reached after max.
heating time (P310)
Boiler not ready on time for
final rinse (temperature or
level not reached)
Boiler heating defective
(welding beads)
Acknowledge
message, further
operation possible
Allow the program to
end without operator
intervention
206 Wash time increase
Temperature sensor
defective
Boiler contactor defective,
circuit breaker triggered
No signal from I/O circuit
board
Call service
technician if this
occurs more often
Short-circuit of boiler
210
Sensor defective
temperature sensor
Sensor position not correct
Plug contact not connected
properly
Further operation not
possible
Interruption of boiler
211
temperature sensor
Call service
technician
“Actual” boiler
212 temperature too high Incorrect sensor/defective
(>95°C) sensor
Contactor contact sticking
9020132