Home > MEIKO > Meiko FV 40.2 Glass and Dishwasher

Meiko FV 40.2 Glass and Dishwasher

Model  
F
V
40.2/40.2G  
8.2  
Electrical installation  
WARNING Danger to life from electric shock  
Work on the electrical system must only be conducted by qualified personnel  
who comply with the electrotechnical rules.  
Disconnect the machine from the power supply before removing any casing  
parts or working on the electrical system. To do this, turn the local main  
switch to OFF and ensure that it cannot be switched back on again.  
Attach all housing parts again before switching on the voltage again.  
1. To do this, turn the local main  
2. Route the electrical supply line  
through the strain relief (1) from  
below and to the main connection  
terminal block (2).  
switch to OFF and ensure that it  
cannot be switched back on again.  
3. Fasten the supply line using the  
strain relief (1). You should leave  
enough slack in the supply line to  
prevent stress on the connections.  
4. Connect the supply line in accordance with the figure and the wiring diagram.  