SHARP SDW6506JS 24 Front Control Dishwasher
INSTALLATION PREPARATION
• Use only copper wire.
METHOD 2 – HIGH DRAIN WITH WASTE TEE OR
DISPOSER
• Wiring must be 2-wire with ground.
• Use a UL Listed/CSA Approved metallic strain relief.
Provide a method to attach drain hose to underside of countertop.
• Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA No. 70-latest edition and all local codes and ordinances.
32"
• If the electrical supply does not meet the above requirements, call
a licensed, qualified electrician before proceeding.
32"
min.
min.
18"
min.
18"
min.
GROUNDING INSTRUCTIONS
• The dishwasher must be connected to a grounded metal,
permanent wiring system, or an equipment grounding conductor
must be run with the circuit conductors and be connected to the
equipment grounding terminal or lead on the dishwasher.
FIGURE D
Install waste tee or disposer and air gap according to manufacturer’s
instructions.
POWER CORD CONNECTIONS
• Use a power cord with connections that comply with the National
Electrical Code, Section 422 and/or local codes and ordinances.
ELECTRICAL REQUIREMENTS
WARNING
• Recommended cord length is 54" minimum and 64" maximum.
ELECTRICAL SHOCK HAZARD
• A power cord kit is available for purchase from an authorized
parts dealer.
• Installation and service must be performed by a
qualified installer or service agency.
• Always disconnect the power before servicing
this unit.
DIRECT WIRE CONNECTIONS
Use flexible, armored or nonmetallic sheathed, copper wire with
grounding wire that meets the wiring requirements for your local
codes and ordinances.
• This appliance must be properly grounded.
• Failure to do so could result in death, fire or
electrical shock.
CABINET PREPARATION
• The wiring may enter the opening from either side, rear or the
floor within the shaded area.
FOR PERSONAL SAFETY: Remove house fuse or
open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with
this appliance.
1
• Cut a 1 /2" maximum diameter hole to allow the electrical cable.
The hole must be free of sharp edges. If the cabinet wall is metal,
the hole edge must be covered with a bushing.
To ensure electrical safety, installation of an Earth
Leakage Circuit Breaker (ELCB) is recommended to
prevent electrical shocks and other electrical hazards
• Cable direct connections may pass through the same hole as the
drain hose and hot water line, if convenient. If cabinet wall is
metal, the hole edge must be covered with a bushing.
NOTE: Power cords with plug must pass through a separate hole.
IMPORTANT
• The dishwasher must be supplied with 120 volt, 60 Hz. power
supply and connected to a dedicated, properly grounded branch
circuit, protected by a 15 or 20 ampere circuit breaker or time
delay fuse.
• Maximum of two field wiring supply conductors (12 AWG
maximum) plus one grounding conductor are permitted in the
terminal box.
6
| General | Details |
|---|---|
| Name | SHARP SDW6506JS 24 Front Control Dishwasher |
| Make | Sharp |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.37 MB |

SHARP SDW6506JS 24 Front Dishwasher

SHARP SDW6888JS Smart Dishwasher

SHARP QW-NA1BF47EI-EU Series Dishwasher

SHARP QW-NA24S42DI-EE Dishwasher

SHARP SDW6767HS Dishwasher

SHARP SDW6767HS Slide In Smart Dishwasher

SHARP SDW6767HS Smart Dishwasher

SHARP QW-NA26F39DI-EN Dishwasher

SHARP QW-NS1CF49EI-ES Dishwasher

SHARP SDW6757ES Dishwasher