Installation and Operation Manual  
Uncoil the drain hose and route through the supplied  
bushing located on the back of the machine base.  
Note that:  
The connection between machine and building drain  
must not exceed a maximum height of 34” above  
finished floor.  
Drain must have a minimum flow capacity of 5 gallons  
per minute. If DWT is on the machine, the drain must  
have a minimum flow capacity of 15 gallons per  
minute.  
Bushing  
If a grease trap is required by code, it should have a minimum flow capacity of 15 gallons per  
minute.  
A pumped drain air gap kit is available using accessory code PUMPDRN-AIRGAP or service kit  
part number 00-562492. Refer to installation instructions included with kit.  
If machine is located directly above a floor drain, a knockout in the bottom of the dish machine  
is provided for the drain hose.  
Use care not to kink the drain hose.  
Replace the rear cover panel.  
Replace the rear cover panel top.  
NOTICE!  
Drain connection  
An improper drain connection or a kinked hose could result in reduced machine  
performance and errors. An air gap connection is the preferred connection method.  
P
(Meets Co
Incorrect  
Acceptable  
F41220 (August 2022)  
Ver2.0  
Page 22 of 60  
GeneralDetails
NameCenterline CDH ML-130374 Commercial Dishwasher
MakeCenterline
LanguageEnglish
FiletypePDF (Download)
File size1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Centerline CUH-130363 Commercial Dishwasher
Centerline CUH-130363 Commercial Dishwasher
centerline CDH-1 51 Racks Hour Door Type Dishwasher
centerline CDH-1 51 Racks Hour Door Type Dishwasher

Centerline CDH ML-130374 Commercial Dishwasher