5.9 Connecting to the power supply
WARNING!
Risk of electric shock
Electrical and grounding connections must comply with the applicable portions of the
National Electrical Code, NFPA 70 (latest edition) and/or other local electrical codes.
Disconnect the electrical power to the machine and follow lockout/tagout
procedures.
5.9.1 Electrical Data
Refer to the sizing diagram located inside the front trim panel and to the data label on the lower, right
side of the machine for service size requirements when connecting the dishwasher. Also, refer to the
Electrical Data, shown below.
NOTICE!
Supply connections
For supply connections, use copper wire only rated at 90°C minimum.
The dish machine is not provided with internal GFCI protection.
A fused disconnect switch or circuit breaker (customer supplied) must be installed
in the electrical service line supplying this dishwasher and should meet the
requirements of your local electrical code.
ELECTRICAL DATA
Minimum
Supply Circuit
Conductor
Ampacity
Maximum
Protective
Device
Rated
Ampacity
Model
Volts/Hertz
Phase
Ampacity
208/60
240/60
208/60
240/60
35.0
35.0
31.7
31.7
40
40
40
40
40
40
40
40
3Ø
CDH
EDH
1Ø
1Ø
CDL
EDL
120/60
17.1
20
20
Compiled in accordance with the National Electrical Code NFPA-70 (latest addition).