Home > Centerline > Centerline CDH ML-130374 Commercial Dishwasher
Centerline CDH ML-130374 Commercial Dishwasher
Installation and Operation Manual
CENTERLINE™ ECOLINE™
Detergent Dispenser
Terminals DET1 and DET2 on 4TB are supplied with controlled 120V voltage. They are ON during the
wash cycle and OFF between cycles, when machine is in delime cycle, or when the machine power
supply is off.
Terminals L1 and L2 on 5TB are supplied with fused machine line voltage for convenience in powering
detergent dispensing equipment. The maximum rating for any equipment connected to L1 and L2 is 2.0
amps at line voltage.
Rinse Agent Dispenser
Terminals RNS1 and RNS2 on 4TB are supplied with controlled 120V voltage. They are ON during the
rinse cycle and OFF between cycles, when machine is in delime cycle, or when the machine power
supply is OFF.
Terminals L1 and L2 on 5TB are supplied with fused machine line voltage for convenience in powering
rinse agent dispensing equipment. The maximum rating for any equipment connected to L1 and L2 is
2.0 amps at line voltage.
NOTICE!
DET1, DET2, RNS1, and RNS2 Connections
The maximum rating for detergent or rinse agent dispenser control connected to
DET1, DET2, RNS1, and RNS2 is 100 mA at 120V voltage.
Use UL listed 600-volt minimum insulated wire for the connections.
Splice connections, if required, must be made in the feeder transformer junction
box (supplied by others) – not in the main controls enclosure.
Strain relief fittings must be provided for all wiring.
208-240V, 2.0A MAX
L2
L1
Transformer
(By Others)
Detergent
Dispenser
Transformer
(By Others)
Rinse Agent
Dispenser
Page 31 of 60
Ver2.0
F41220 (August 2022)