Home > Centerline > Centerline CDH ML-130374 Commercial Dishwasher

Centerline CDH ML-130374 Commercial Dishwasher

Installation and Operation Manual  
CENTERLINE™ ECOLINE™  
9.7.3 Inspecting sanitizer supply  
Verify that the ball in the sanitizer float sight is above the  
“EMPTY” line.  
If the ball is below the “EMPTY” line, inspect the  
sanitizer container for chemical present.  
Prime the sanitizer line if needed (refer to 9.7.2).  
Verify that the supply tube is correctly inserted with the suction filter at the bottom  
of the container.  
If air bubbles (large gaps) are present in sanitizer line prime (refer to 9.7.2)  
9.7.4 Sanitizer supply level sensor (Optional)  
Make sure the bottle level sensor is correctly inserted into bottle with  
float sensor at bottom of container.  
If air bubbles (large gaps) are present in the sanitizer line prime  
(refer to 9.7.2)  
9.8 Temperature display units  
Top display shows “08”  
Bottom display shows current temperature units: (Default is “F”)  
Page 53 of 60  
Ver2.0  
F41220 (August 2022)  
     