Centerline CDH ML-130374 Commercial Dishwasher

CENTERLINE™ ECOLINE™  
Installation and Operation Manual  
Error  
code  
Symptom  
Possible Solution*  
1. Press the power button to power off and drain tank.  
2. Restart as normal.  
Booster Heat Up Time  
Exceeded at Startup  
3. If error continue to display, unplug the machine from the wall. If  
unit is hardwired, turn circuit breaker off then back on.  
4. If error continues to display, possible tripped high limit or heating  
element malfunction – contact Hobart Service.  
30  
1. System exceeded maximum fill time.  
2. Press the power button to power off machine.  
3. Verify supply hose is not pinched or kinked.  
4. Check that water is being supplied to machine.  
5. Restart as normal.  
31 Fill Error  
6. If error continues to display, possible fill valve malfunction –  
contact Hobart Service.  
10.2 Information  
The following notes are displayed with a combination of letters in the display in the display.  
Display  
Reason  
Remedy  
do  
or  
Filling, washing draining or delime program  
interrupted  
Close door  
F41220 (August 2022)  
Ver2.0  
Page 58 of 60  
 
GeneralDetails
NameCenterline CDH ML-130374 Commercial Dishwasher
MakeCenterline
LanguageEnglish
FiletypePDF (Download)
File size1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Centerline CUH-130363 Commercial Dishwasher
Centerline CUH-130363 Commercial Dishwasher
centerline CDH-1 51 Racks Hour Door Type Dishwasher
centerline CDH-1 51 Racks Hour Door Type Dishwasher

Centerline CDH ML-130374 Commercial Dishwasher