SYMPTOM  
POSSIBLE CAUSE  
Inadequate Rinse.  
1. Dirty line strainer (Fig. 35) causing reduced water flow. Turn off water supply,  
remove strainer cap and screen. Clean screen. Reassemble.  
2. Low supply line pressure or dirty in-line rinse arm strainer.  
3. Clogged rinse nozzle(s).  
NOTE: CLeR models have two supply lines.  
Continuous Rinse  
1. Rinse actuator (Fig. 36) not moving freely.  
Disconnect the electrical power to the machine  
and follow lockout / tagout procedures. There may be multiple  
circuits. Be sure all circuits are disconnected. Check actuator  
for free movement.  
2. Check for foreign object in mechanism, i.e., silverware.  
3. Rinse valve failed or jammed open.  
4. Standpipe(s) not seated properly — water draining and fill remains on.  
No Wash Tank Heat,  
Tanks Not Heating.  
1. The machine is equipped with low water safety devices which shut  
off heat if water level drops. Check for proper water level.  
2. Circuit breaker(s) to heat system tripped (electric heat).  
3. Check heat float for debris and free movement.  
4. Overtemp protector tripped or failed heating element (electric heat). Contact  
Hobart Service.  
5. The main gas supply valve is not open (gas heat).  
6. Make sure all standpipes are properly seated.  
7. Steam supply valve(s) are not opened completely or supply pressure is  
too low (steam heat).  
8. Bucket trap not functioning correctly (steam heat).  
9. Improperly operating steam solenoid valve(s) (steam heat).  
No or Slow Fill.  
1. Door(s) are open.  
2. Main fill (water supply valve) could be closed.  
3. Upper and / or lower fill floats do not move freely.  
4. Dirty line strainer (Fig. 35) causingreduced water flow. Turn off water  
supply, remove strainer cap and withdraw and clean screens. Reassemble.  
5. Problem with solenoid valve.  
6. Low incoming water supply pressure.  
7. Drain(s) open.  
8. Standpipe(s) not seated properly or placed in wrong tank.  
Leaking Vacuum Breaker.  
Excessive Steam  
1. Foreign material or corrosion could be preventing proper valve  
operation. Shut off all incoming water supply line(s). Unscrew and lift  
bonnet from valve body. Clean valve and reassemble.  
1. Vent stack damper not adjusted properly.  
2. CLeR canopy hood installation: canopy hood fan not functioning correctly.  
LINE STRAINER  
INCOMING WATER  
CLEANOUT  
RINSE ACTUATOR  
Fig. 36  
Fig. 35  
NOTE: If symptom(s) persists after possible causes have been checked, contact  
your local Hobart Service office.  
– 38 –  
GeneralDetails
NameHOBART CLCS66e ML Series Dishwasher
MakeHOBART
LanguageEnglish
FiletypePDF (Download)
File size2.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
HOBART AM16 Commercial Dishwasher
HOBART AM16 Commercial Dishwasher
HOBART S.48820 Commercial Dishwasher
HOBART S.48820 Commercial Dishwasher

HOBART CLCS66e ML Series Dishwasher