HOBART CLCS66e ML Series Dishwasher
SYMPTOM
POSSIBLE CAUSE
Inadequate Rinse.
1. Dirty line strainer (Fig. 35) causing reduced water flow. Turn off water supply,
remove strainer cap and screen. Clean screen. Reassemble.
2. Low supply line pressure or dirty in-line rinse arm strainer.
3. Clogged rinse nozzle(s).
NOTE: CLeR models have two supply lines.
Continuous Rinse
1. Rinse actuator (Fig. 36) not moving freely.
Disconnect the electrical power to the machine
and follow lockout / tagout procedures. There may be multiple
circuits. Be sure all circuits are disconnected. Check actuator
for free movement.
2. Check for foreign object in mechanism, i.e., silverware.
3. Rinse valve failed or jammed open.
4. Standpipe(s) not seated properly — water draining and fill remains on.
No Wash Tank Heat,
Tanks Not Heating.
1. The machine is equipped with low water safety devices which shut
off heat if water level drops. Check for proper water level.
2. Circuit breaker(s) to heat system tripped (electric heat).
3. Check heat float for debris and free movement.
4. Overtemp protector tripped or failed heating element (electric heat). Contact
Hobart Service.
5. The main gas supply valve is not open (gas heat).
6. Make sure all standpipes are properly seated.
7. Steam supply valve(s) are not opened completely or supply pressure is
too low (steam heat).
8. Bucket trap not functioning correctly (steam heat).
9. Improperly operating steam solenoid valve(s) (steam heat).
No or Slow Fill.
1. Door(s) are open.
2. Main fill (water supply valve) could be closed.
3. Upper and / or lower fill floats do not move freely.
4. Dirty line strainer (Fig. 35) causingreduced water flow. Turn off water
supply, remove strainer cap and withdraw and clean screens. Reassemble.
5. Problem with solenoid valve.
6. Low incoming water supply pressure.
7. Drain(s) open.
8. Standpipe(s) not seated properly or placed in wrong tank.
Leaking Vacuum Breaker.
Excessive Steam
1. Foreign material or corrosion could be preventing proper valve
operation. Shut off all incoming water supply line(s). Unscrew and lift
bonnet from valve body. Clean valve and reassemble.
1. Vent stack damper not adjusted properly.
2. CLeR canopy hood installation: canopy hood fan not functioning correctly.
LINE STRAINER
INCOMING WATER
CLEANOUT
RINSE ACTUATOR
Fig. 36
Fig. 35
NOTE: If symptom(s) persists after possible causes have been checked, contact
your local Hobart Service office.