Single-Point Electrical Connection (S.P.E.C.) — Three-Phase Only
All three-phase machines are prewired for single-point electrical connection for the
motors, controls and electric tank heaters; however, electric tank heat machines
(three-phase only) may be field wired for separate electrical connections. Refer
to the wiring diagram inside the control box lid. NOTE: The booster heater, when
supplied, is always provided with a separate electrical connection.
Motor Rotation — Three-Phase Only
Before placing a three-phase machine into service, check to verify that
the conveyor motor rotates in the correct direction. (The control box is pre-wired
at the factory so that all motors are phased together. If the conveyor motor rotation
is correct, the pump motors will also be correct.) Incorrect rotation will result in
unacceptable performance.
To check the conveyor motor's rotation:
Close the machine doors, press POWER on the keypad and allow the machine to
fill. When the machine is completely filled, press POWER to turn the machine off.
Disconnect the electrical power to the machine and follow
lockout/tagout procedures. There may be multiple circuits. Be sure all
circuits are disconnected.
Remove the front panel below the doors. Reconnect the electrical power to the
machine, being careful not to touch any uninsulated electrical parts exposed by
removing the front panel. Press START / ENTER on the keypad and verify proper
motor rotation, as follows:
The conveyor motor and clutch must rotate counterclockwise for machines with
right-to-left operation, and clockwise for machines with left-to-right operation.
If the rotation of the conveyor motor is correct, press POWER to turn the machine
off. Disconnect electrical power to the machine, and replace the front panel.
Iftheconveyormotordoesnotrotateintheproperdirection, disconnecttheelectrical
power to the machine. At the machine control box on top of the machine, reverse
any two of the incoming power supply leads, either the leads to the entire machine,
or the leads to the motor and controls if they are wired independent of the heaters.
Do not simply reverse the leads to the conveyor motor.
Reconnect the electrical power to the machine. Re-check the conveyor motor's
rotation. The conveyor motor and clutch must rotate counterclockwise for machines
with right-to-left operation, and clockwise for machines with left-to-right operation.
If the rotation of the conveyor motor is correct, press POWER to turn the machine
off. Disconnect the electrical power to the machine. Replace the top cover to the
control box, and replace the front panel.