Home > HOBART > HOBART CLCS66e ML Series Dishwasher

HOBART CLCS66e ML Series Dishwasher

PARAMETERS MENU — TABLE 1  
Parameter  
Name  
Description  
Possible  
Values  
Default  
Value  
Sanitizing Mode  
Sets the operating temperatures that regulate the tank heaters and High Temp.  
High  
the internal booster (if provided): high temperature sanitizing mode,  
or low temperature, chemical sanitizing mode.  
or  
Temp.  
Low Temp.  
30 to 180  
(in 15 second  
increments)  
Auto-Timer  
Pumps and conveyor shut down after this period of inactivity to save  
energy. Refer to page 27.  
45  
Low FR Temp.  
Alert  
Enables or disables a visual alert on the display that indicates that  
Final Rinse water temperature is below the required minimum of  
180°F (82°C). When enabled, a message will display notifying the  
user of this condition. However, machine operation will not change  
and ware will continue to run through the machine as expected.  
After the temperature increases past the minimum, the message  
stops. When disabled, there will be no extra message indicating  
a low-temperture event; however, the temperature display will still  
show the current Final Rinse water temperature. Refer to page 24.  
Disabled  
or  
Enabled  
Disabled  
Tank Temp. Alert  
Delime Interval  
Displays a message that the water temperature of a certain tank is  
below the minimum required. After the temperature increases past  
the minimum, the message stops. Refer to page 24.  
Disabled  
or  
Enabled  
Disabled  
0
Sets the delime interval from 0 to 1000 hours. Asetting of 0 disables  
this feature. Up arrow increases 10 hours, Down arrow decreases.  
Hold Up or Down arrow for faster movement.  
0
to  
1000  
Dirty Water Mode Disabled: Ignores dirty water. Alert Only: Displays 'Water Change  
Disabled,  
Disabled  
Req'd' after a period of operation but does not require refilling. Alert Alert Only  
&Lockout:Displays'ChangeWaterSoon'for5minutesafteraperiod  
ofoperation;then'WaterChangeReq'd'displaysandmachinecannot  
run until tank(s) are drained and refilled. Refer to page 26.  
or  
Alert &  
Lockout  
Dirty Water  
Interval  
Sets the period (in hours) of rinsing before an alert is shown. This  
option is only available when Dirty Water Mode is set to 'Alert Only'  
or to 'Alert & Lockout'.  
1 – 6  
4
Energy Saver  
Mode (ESM)  
ESM begins after a period of machine inactivity. Up arrow increases 1, 2, 3, 4,  
2
by 1 hour. Down arrow decreases by 1 hour. Refer to page 26.  
5, 6  
Change Mgr.  
Code  
SetsanewSecurityCodeforaccesstotheManagerLevelparameters.  
It is recommended to change this code from the default value and  
store the new code where all kitchen managers, but no operators,  
can access it.  
0000  
to  
8888  
1001  
Edit  
PressSTART/ENTERtoaccesstheCommunicationsSetupMenu,to  
editsettingsfortheNAFEMDataProtocol. RefertoCommunications  
Setup Menu – Table 2, page 35. Press Down arrow or Up arrow to  
move down or up the menu.  
Communications  
Setup?  
Save Settings  
and Exit?  
Press START / ENTER to save the changed settings, exit the  
Parameters Menu and return to the main screen. Any settings  
that were changed are saved and most become active  
immediately. If one or more settings are not activated immediately,  
a message will display indicating that you need to cycle power off  
and on to make them active.  
Cancel Settings  
and Exit?  
Press START / ENTER to exit the Parameters Menu and return to  
the main screen. Any settings that were changed are cancelled and  
revert back to the previously saved values.  
– 35 –  
GeneralDetails
NameHOBART CLCS66e ML Series Dishwasher
MakeHOBART
LanguageEnglish
FiletypePDF (Download)
File size2.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
HOBART AM16 Commercial Dishwasher
HOBART AM16 Commercial Dishwasher
HOBART S.48820 Commercial Dishwasher
HOBART S.48820 Commercial Dishwasher

HOBART CLCS66e ML Series Dishwasher