HOBART CLCS66e ML Series Dishwasher
Optional Equipment Control Connections
Electrical and grounding connections must comply with the
applicable portions of the National Electrical Code, NFPA 70 (latest edition)
and / or other local electrical codes.
Disconnect the electrical power to the machine and follow
lockout / tagout procedures. There may be multiple circuits. Be sure all
circuits are disconnected.
Detergent Feeder
The maximum rating for a detergent dispenser connected to DPS1 and DPS2 is
1.5 amps at line voltage. Refer to Chemical Feeder Installations, page 8.
Rinse Aid Feeder and / or Chemical Sanitizer Feeder
The maximum rating for a rinse aid dispenser and / or chemical sanitizer feeder
connected to RPS1 and RPS2 is 1.5 amps at line voltage. Refer to Chemical
Feeder Installations, page 8.
Vent Fan Control
The maximum rating for a vent fan control connected to VFC1 and VFC2 is 1.5
amps, pilot duty.
CLeR ENERGY RECOVERY SETUP
Certain procedures in this section require electrical test or
measurementswhilepowerisappliedtothemachine.Exerciseextremecaution
atalltimes.Iftestpointsarenoteasilyaccessible,disconnectpowerandfollow
lockout/tagout procedures, attach test equipment and reapply power to test.
Setupproceduresmustbeperformedafterhotandcoldwaterconnections
have been completed, tanks are full, and machine is cold.
1. Verify that both manual hot and cold water supply valves are on.
2. Turn main power to the
THERMISTOR (6QTM)
CONNECTION
machine OFF at customer’s
disconnect.
3. Removethetopcoverfromthe
control box.
4. Remove the end cover at the
unload end of machine.
5. Disconnectthermistor(6QTM)
connection located at the rear
of the coil enclosure assembly
at the back of the machine.
Fig. 13
– 16 –