STEAM CONNECTION (When Machine is Equipped with Steam Tank Heat)
Steam supply pressure must agree with the steam trap (supplied) which
is rated for 10 to 50 psig differential pressure. If flowing pressure exceeds 50 psig,
a pressure regulator (by others) must be installed in the supply line. Steam flow is
controlled by solenoid valves.
For single-tank steam coil installations, two connections are required, one for
supply and one for return. For two-tank steam coil installations, one common supply
connection and two return connections are required.
GAS CONNECTION (When Machine is Equipped with Gas Tank Heat)
Check the gas data plate attached to the dishwasher on the side of the control
box or refer to the tag attached to the gas burner tubing for the type of gas to be
used. All machines are shipped configured for natural gas. If conversion to LP gas
(propane) is required, a conversion kit with instructions is supplied and must be
installed before the machine is operated.
The burner is not adjustable. If flowing gas pressure is above 7" W.C. (natural gas)
or 11" W.C. (propane gas), an additional regulator valve (by others) must be installed
in the supply line. Static incoming line pressure should not exceed 14.0" W.C. for
either propane or natural gas.
The gas supply line to the dishwasher must be provided with a
shut-off valve per code. The appliance and its gas connections must be leak
tested before placing the appliance in operation. Use soapy water for leak
tests. DO NOT use an open flame.
The installation must conform with local codes, or in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1 (latest edition), available from the
American GasAssociation, Inc., 1515 Wilson Blvd.,Arlington, VA22209. In Canada,
comply with CAN/CSA B149.1 and CSA C22.1 (latest editions).
NOTE: For gas line pipe connections, use Loctite 565, Hobart part number 546292,
or a flexible sealant suitable for use with Natural and Propane Gases.
• The appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psig (3.45 kPa).
• The appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig (3.45 kPa).