CLeR AIR FLOW ADJUSTMENT  
1. Turn main power to machine OFF at customer's disconnect.  
2. Open door of dishwasher and insert a dish rack upside down in final rinse zone  
to activate final rinse flow.  
3. Turn main power to machine ON at customer's disconnect.  
4. Press power button on keypad to turn machine on. (Located on front of main  
control box).  
5. Press start button on keypad to turn pumps and final rinse on.  
6. Verify that the tank  
ADJUST DAMPER  
SHAFT TO  
HORIZONTAL  
temperature(s) and final rinse  
temperature are above the  
minimum requirements. (If  
not, press the stop button on  
keypad to turn pumps off and  
allowtemperaturestoheatup.)  
7. Completely close vent by  
adjusting vent stack damper  
shaft to horizontal position.  
8. Ventstackdamperadjustment:  
Fig. 19  
Opening the vent stackdamper too farmay causelow tanktemperatures.  
a) For pant leg vent systems, adjust the vent stack damper shaft until the  
steam escaping from around the bottom of the energy recovery hood and  
curtain is eliminated. (Note: Do not over adjust the damper. Adjust in small  
increments just until the steam is eliminated. If curtain is being drawn in,  
damper is overadjusted.)  
b) For canopy hood vent systems,  
adjust the vent stack damper shaft to  
approximately 15° to 25° open.  
Fig. 20  
– 19 –  
GeneralDetails
NameHOBART CLCS66e ML Series Dishwasher
MakeHOBART
LanguageEnglish
FiletypePDF (Download)
File size2.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
HOBART AM16 Commercial Dishwasher
HOBART AM16 Commercial Dishwasher
HOBART S.48820 Commercial Dishwasher
HOBART S.48820 Commercial Dishwasher

HOBART CLCS66e ML Series Dishwasher